Advertisement

Quick Links

Version
2.4
User Manual
Industrial PCs
OPC5015

Advertisement

Table of Contents
loading

Summary of Contents for ADS-tec OPC5015

  • Page 1 Version User Manual Industrial PCs OPC5015...
  • Page 2 Industrial PCs OPC5015 Product Portfolio Copyright © ads-tec GmbH Raiffeisenstr.14 D-70771 Leinfelden-Echterdingen Germany © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 3: Table Of Contents

    CONNECTION ON THE FACEPLATE ........................20 XTERNAL DRIVES DVI I ......................... 21 NTERFACE 7.10 (IDE ) ................22 ARD DRIVE OMPACT LASH INTERFACE 7.11 PS/2 ........................22 CONNECTION SOFTWARE/DRIVER INSTALLATION ................... 23 © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 4 OFTWARE KEYBOARD TECHNICAL DETAILS ......................25 .......................... 25 ISPLAY ......................25 OMPUTER TECHNICAL DATA .......................... 25 ENERAL DATA SERVICE AND SUPPORT ....................26 10.1 ........................26 UPPORT 10.2 : ........................ 26 OMPANY ADDRESS © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 5: Remarks

    IBM Corp. ® SanDisk is a registered trademark of SanDisk Corp. CompactFlash™ and CF™ are trademarks of SanDisk Corp. We hereby recognize all other locally and internationally known trademarks and product names. © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 6: Copyright

    1.6 A MBIENT CONDITIONS The device can be operated in the following ambient conditions. The device warranty will be rendered invalid upon noncompliance with these specifications. ads-tec shall not be held responsible for damages resulting from improper handling. • Temperature for devices with hard disk drives during use 0 …...
  • Page 7: Standards

    Power plug: 3 pin Phoenix Contact COMBICON MC 1.5/3-GF-3.81 feed- • through header (already mounted in the device socket) Fastener set for control cabinet • Service CD • Optional components Operating system • © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 8: Safety Information

    Measures to prevent heat accumulation should be implemented if the device is installed in a console, casing or similar enclosing structure. The maximum permissible ambient temperature should not be exceeded. © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 9: Damage Due To Improper Usage

    The lithium battery can only be replaced by the same type or a type recommended by the manufacturer. The used lithium battery should be disposed of in accordance with local legal regulations. © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 10: Mounting

    Devices with drives should only be installed in an upright position. Any deviations from this should be agreed upon with ads-tec GmbH. The front is only IP65 protected if mounted correctly. If the device is delivered with a CD/DVD-ROM drive, then there should be sufficient space provided (approx.
  • Page 11: Mounting Procedure

    If additional grounding conductors are attached to a grounding screw, a wire diameter of at least 2.5 mm² is specified. © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 12: Startup

    Cable shielding of a data cable has to be connected to the plug connection casing (EMC). The interfaces have to be enabled in the embedded operating system and the matching drivers have to be installed to be able to use the interfaces. © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 13: Tartup Procedure

    (e.g. smoke emission from the device, etc.). If damages are found, immediately shut down the device and protect it against unintentional startup. © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 14: Operation

    The settings for these adjustments will not be displayed on the screen. The button functions can be modified to accommodate individual customer requirements. The functions described above only represent factory settings. © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 15: Software Keyboard

    The most recent activated status is saved upon closing the software keyboard (alphabetic/numeric block or F1  F12) and this status will be displayed again the next time the software keyboard is invoked. © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 16: External Keyboard

    USB interface. The touch screen is connected internally to a USB interface. The driver required to use the touch screen is integrated in the respective operating system or can be installed from the provided service CD. © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 17: Status Indicators

    The following signals are indicated: • LED green Device is on (power on). • LED orange The switch for changing the display setting is pressed. • LED off The device is off. (power off). © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 18: Interfaces

    "Technical Details" s section. 7.4 USB CONNECTIONS The USB interfaces c can be used to connect peripheral devices with U USB plugs. PIN NUMBER SIGNAL NAME © ads-tec GmbH • Raiffeisenst tr.14 • 70771 Leinfelden-Echterdingen...
  • Page 19: Network Connection (Rj45)

    The plastic cover is to be closed carefully after having used the USB interface, because otherwise the protection class IP65 is not ensured on the front. © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 20: External Drives

    It is not permissible to connect or disconnect an external drive while the device is running, because it can not be ruled out that the drive is in use at this time. Non- adherence can cause loss of data! © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 21: Dvi Interface

    Panel PC works like a DVI-A Interface. The video signals are transferred analog. PIN-NUMMER SIGNAL NAME Analog vertical sync Analog Red Analog Green Analog Blue Analog Horizontal Sync Analog GND Return: (analog R, G, B) © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echte erdingen...
  • Page 22: Ps/2 Connection

    A mouse and a keyb board can be connected to the two PS/2 connecto ors. The connectors on the device are color- -coded to indicate the intended use. PIN NUMBER SIGNAL NAME Data Clock © ads-tec GmbH • Raiffeisenst tr.14 • 70771 Leinfelden-Echterdingen...
  • Page 23: Software/Driver Installation

    You can use a USB stick containing an image file to perform a complete install of Windows CE.net or Windows XP Embedded. You can obtain the required image from ads-tec or the ASSIX online portal. © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 24: Touch Screen Driver Installation (Windows 2000/Xp)

    Note: Basic and advanced settings can be made for software keyboard. The readme file in the software keyboard installation directory contains more information pertaining to this. © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 25: Technical Details

    376 mm x 299 mm (W x H) Weight approx. 6 kg Protection class front, IP 65 Power consumption 26 Watts (type) Current consumption 2 - 2.5 Amperes during use Max. switch-on current 7 Amperes (2ms) © ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen...
  • Page 26: Service And Support

    Only the system manufacturer can respond to questions pertaining to special configurations and software installations in each case. No support can be provided for devices that were not purchased directly from ads-tec. The ads-tec partners responsible for installation will provide the support required in these cases.