Grounding; Wiring - Honeywell SMARTBOX Owner's Manual

Controller for wind turbine model wt6500
Table of Contents

Advertisement

11

Grounding

Wiring

SMARTBOX™ Controller for HONEYWELL™ Wind Turbine WT6500 Owner's Manual - Rev14
The SMARTBOX™ Controller is designed to work only with the HONEYWELL™
Wind Turbine. The turbine uses a negative-grounded electrical system. Grounding for
the turbine, battery and AC circuits are provided inside the wiring compartment. Each
ground connection can accommodate up to #6 AWG wire size.
GFI: A fuse rated at .5A 250V, accessible from the bottom of the wiring compartment,
grounds the negative conductor of the turbine and provides turbine ground-fault
protection. Only a Littelfuse 0312.500HXP or equivalent fuse should be used as a
replacement.
SHOCK HAZARD
DO NOT connect the battery negative to ground. NEC
requirements specify that the battery negative ground must
be done only through the 1A fuse. Bonding the battery
negative to ground will disable the turbine's ground fault
protection and will result in improper operation. The battery
compartment should be grounded if made of metal. Failure
to follow this warning may result in death, personal injury or
property damage.
SHOCK HAZARD AND FIRE HAZARD
Fuses must only be replaced by qualified service personnel,
such as a certified electrician or technician. For continued
protection again risk of fire, replace only with the same type
and rating of fuse.
in death, personal injury or property damage.
SHOCK HAZARD
Disconnect wind and battery circuits before removing the
grounding connections or before removing or installing
the fuse. Wait at least 5 minutes for the internal circuitry to
discharge before servicing the unit.
warning may result in death, personal injury or property
damage.
PROFESSIONAL INSTALLATION: REQUIRED
Installations must meet all local electrical codes. Installations for the equipment should
only be performed by a qualified electrician or an Authorized Installer.
SHOCK HAZARD
Disconnect turbine and battery circuits before wiring.
Turn off all power before wiring.
this warning may result in death, personal injury or
property damage.
Get other manuals https://www.bkmanuals.com
Failure to follow this warning may result
Failure to follow this
Failure to follow
SMARTBOX Installation

Advertisement

Table of Contents
loading

Table of Contents