4 Defaulting the controller and configuring the IP address

This section describes the following.

4.1 Defaulting the Controller and IP Address Configuration

4.1.1 Factory default the Controller (DIP switch 2)

4.1.2 DHCP/static IP addressing (DIP switch 1)
4.1.3 Defaulting the static IP address
4.1.4 Changing static IP address on the ACTpro Controller
4.1 Defaulting the Controller and IP Address Configuration
The ACTpro-1500 has two DIP switches.
DIP switch 1: DHCP
l
Enables DHCP or Static IP address mode.
DIP switch 2: DEFAULT
l
Defaults the controller or the Static IP address.
4.1.1 Factory default the Controller (DIP switch 2)
The ACTpro Controller may be defaulted to factory settings. This will completely erase the controller
memory. All information including card details will be erased and the static IP address will be reset to
192.168.1.60.
To default the ACTpro Controller:
1. Power down the ACTpro Controller.
2. Set the DEFAULT DIP switch 2 to ON.
3. Hold down the Tamper spring.
4. Apply power to the ACTpro Controller.
5. Wait approximately 5 seconds, until the controller confirms default completed by sounding the
buzzer.
6. Release the Tamper.
7. Power down the ACTpro Controller.
8. Set the DEFAULT DIP switch to OFF.
9. Re-apply power.