4.1.2 DHCP/static IP addressing (DIP switch 1)

The ACTpro Controller is shipped with the DHCP enabled and can be configured to obtain an IP address
from a DHCP server or use a static IP address.
1. Power down the ACTpro Controller.
2. Set the DIP switch to its new position.
a. DHCP IP addressing: Move DIP switch 1 to ON
b. Static IP addressing: Move DIP switch 1 to OFF
Note: Default static IP address is 192.168.1.60.
3. Re-apply power to the board.

4.1.3 Defaulting the static IP address

The static IP address can be reset to the default value of 192.168.1.60.
1. Power down the ACTpro Controller.
2. Set the DHCP DIP switch 1 to OFF.
3. Set the DEFAULT DIP switch 2 to ON.
4. Re-apply power.
5. Wait approximately 5 seconds, until the controller confirms default completed by sounding the
buzzer.
6. Remove power.
7. Set the DEFAULT DIP switch 2 to OFF.
8. Re-apply power.
Note: The static IP address can be changed via the web interface or using ACT Software.

4.1.4 Changing static IP address on the ACTpro Controller

1. Connect ACTpro Controller to the IP network.
2. Open a web browser on a PC (for example, Microsoft Internet Explorer, Google Chrome, etc.).
3. Enter http://<NetBIOS address>, e.g. http://ACT1500-07116
4. Logon details:
Username: installer
Password: 999999
© Vanderbilt 2020
Ensure nothing is connected to the tamper input terminal and the tamper spring is
not pressed, otherwise the following steps will factory default the controller losing
all information.