SECTION 1: SAFETY PRECAUTIONS ..........................................................................2
SECTION 2: INTRODUCTION ......................................................................................4
SECTION 3: MIG GUN SPECIFICATIONS.....................................................................4
SECTION 4: MIG GUN INSTALLATION ........................................................................4
SECTION 6: CABLEHOZ® REPAIR .............................................................................6
SECTION 7: TROUBLESHOOTING ...............................................................................6
SECTION 8: CONSUMABLES ......................................................................................6
SECTION 9: REPLACEMENT PARTS ...........................................................................8
SECTION 10: STATEMENT OF WARRANTY ................................................................9

SECTION 1: SAFETY PRECAUTIONS

WARNING
SERIOUS INJURY OR DEATH may result if welding and cutting equipment is not prop-
erly installed, used, and maintained. Misuse of this equipment and other unsafe prac-
tices can be hazardous. The operator, supervisor, and helper must read and understand
the following safety warnings and instructions before installing or using any welding
or cutting equipment, and be aware of the dangers of the welding or cutting process.
Training and proper supervision are important for a safe work place. Keep these in-
structions for future use. Additional recommended safety and operating information is
referenced in each section.
WARNING
This product contains chemicals, including lead, known to the State of California to
cause birth defects and other reproductive harm. Wash hands after handling.
ELECTRIC SHOCK CAN CAUSE INJURY OR DEATH
Install and maintain equipment in accordance with the National Electrical Code
(NFPA 70) and local codes. Do not service or repair equipment with power on.
Do not operate equipment with protective insulators or covers removed.
Service or repair to equipment must be done by qualified and/or trained
personnel only.
Do not contact electrically live parts. Always wear dry welding gloves that are in good
condition. Aluminized, protective clothing can become part of the electrical path. Keep oxygen
cylinders, chains, wires, ropes, cranes, and hoists away from any part of the electrical path.
All ground connections must be checked periodically to determine if they are mechanically
strong, and electrically adequate for the required current. When engaged in AC welding/
cutting under wet conditions or where perspiration is a factor, the use of automatic controls
for reducing the no load voltage is recommended to reduce shock hazards. Accidental contact
must be prevented when using open circuit voltage exceeding 80 volts AC, or 100 volts DC by
adequate insulation or other means. When welding is to be suspended for any length of time,

Table of Contents

Mesures de sécurité ......................................................................... 2
2.01
How to Use this Manual ................................................................... 4
2.02
Receipt of Equipment ....................................................................... 4
2.03
Description ....................................................................................... 4
3.01
MIG Gun Classification ..................................................................... 4
3.02
Duty Cycle ........................................................................................ 4
3.03
MIG Gun Part Number Identification ................................................ 4
4.01
Direct Plug MIG Gun Installation ...................................................... 4
5.01
Installing or Replacing VELOCITY2 Contact Tip ............................... 5
5.02
Conduit Identification ....................................................................... 5
Conduit Removal .............................................................................. 5
Conduit Installation .......................................................................... 5
5.03
5.04
Replace Conductor Tube .................................................................. 6
6.01
Cablehoz® Repair ............................................................................ 6
8.01
Tips and Nozzles .............................................................................. 6
8.02
Conduit ............................................................................................ 7
8.03
Conductor tube ................................................................................ 7
10.01
Warranty Schedule ........................................................................... 9

MESURES DE SÉCURITÉ

AVERTISSEMENT
DES BLESSURES GRAVES OU MORTELLES peuvent résulter d'une installation, d'un
usage ou d'un entretien inadéquat de l' é quipement de soudage et de découpage.
Une mauvaise utilisation de cet équipement et d'autres pratiques risquées peuvent
être dangereuses. L' o pérateur, le superviseur et l'aide doivent lire et comprendre les
avertissements et les instructions de sécurité suivantes avant d'installer ou d'utiliser
tout équipement de soudage ou de découpage et être conscients des dangers inhérents
aux processus de soudage et de découpage. Une formation et une supervision adaptées
sont importantes pour assurer un lieu de travail sûr. Gardez ces instructions pour une
utilisation future. Chaque section comporte des informations supplémentaires de sécu-
rité et de fonctionnement.
AVERTISSEMENT
Ce produitcontient des produits chimiques, notamment du plomb, reconnu par l'Étatde
la Californie pour causerdes malformations congénitaleset d'autresdommages touchant
le système reproductif. Se laver les mainsaprès manipulation.
UN CHOC ÉLECTRIQUE PEUT CAUSER DES BLESSURES OU LA MORT
L'installation et l'entretien de l'équipement doivent être conformes au Code national
de l'électricité NFPA 70 et aux codes locaux. N'effectuez pas l'entretien ou la
réparation d'équipement en marche. N'opérez pas l'équipement sans isolateurs ou
caches de protection. L'entretien ou la réparation de l'équipement doivent être
effectués uniquement par un technicien qualifié ou par du personnel formé.
Ne touchez pas aux pièces électriques chargées. Portez toujours des gants de soudage au sec
et en bon état. Les vêtements de protection aluminisés peuvent devenir une partie du chemin
électrique. Éloignez les bouteilles d'oxygène, les chaînes, les câbles métalliques, les appareils
de levage, les treuils et les élévateurs de toute partie du circuit électrique. Toutes les liaisons de
terre doivent être vérifiées périodiquement pour déterminer si elles sont solides et appropriées
au courant demandé. En cas de soudage ou de découpage en courant alternatif dans des