III-3
Diag I
No function
Depress the enable pedal
Nothing
Hourmeter condition
On
Discharge indicator condition
Green
Tilt signaled
Yes
26
BREAKDOWN
Preliminary checks
Battery charged correctly.
Battery connections in good condition.
Fuse [F1] 325A not triggered.
Circuit breakers on "ON".
- [CB1] : 5A face LCB.
- [CB2] : 0,63A inside LCB.
Battery circuit breaker pulled out.
Emergency stop switches pulled out.
Key selector on " I " .
Speed selector on "
The machine is on flat and horizontal ground.
Led enable lit
See page "Diag I-2"
Press on reset sw itch then on enable
Pump turns
See page "Diag I-4"
".
See page "Diag I-1"
Off
Off
See page "Diag I-3"
Not
Toucan 861
III-3
Pump turns
Red
Pump does not turn
See page "Diag I-5"