III-3
Diag II
Tilt alarm activated
as soon as the mast leaves
its low ered position
All functions are stopped
Check the condition of the sensor
- led red -
Measure the voltage between contacts
n° 2 (+) and 1 (-) of CR6 (tilt connector).
Measure the voltage at contact n°3
of CR6 (tilt connector).
Measure the voltage at terminal block
LCB - wire rep.17 -
Check / repair the connections of
diode D9 or replace D9.
32
BREAKDOWN
off
24V
24V
24V
Preliminary checks
The machine works normally in lowered position.
Battery charged correctly.
Battery connections in good condition.
The machine is on flat and horizontal ground.
on
Check / adjust the tilt indicator or
replace the tilt indicator.
Check / repair the connections of
< 24V
wires rep. 6 & 11 in the LCB.
Check / repair the link cable
LCB / Tilt.
Check / repair the connector
(see § 3-3-2).
< 24V
Check / repair the connector
(see § 3-3-2).
Replace the tilt indicator.
< 24V
Check / repair the link cable
LCB / tilt.
Check / repair the block connections.
Toucan 861
III-3
Models
Updated 04-06

Advertisement