JLG TOUCAN 861 Service Manual page 40

Table of Contents

Advertisement

III-3
Diag VII
Mast lowering problems
No lowering
Measure voltage on terminals of coil MDE.
Measure the impedance of MDE -coil disconnected-
18 - 25
Check the electrovalve (operation).
Correct
Check the load holding valve (operation).
Correct
Contact JLG Product Support.
Lowering only if enable is kept depressed
Check the check valve on pump outlet for leaks.
Correct
Check the piloted check valve on
auxillary manifold for leaks.
Correct
Check the check solenoid valve MDE for leaks.
Correct
Check the general pressure relief valve for leaks.
Correct
Check the load holding valve (leak on piloting).
Correct
Contact JLG Product Support.
Lowering at reduced speed
Check the flow regulator on the cylinder.
Correct
Excessive friction
Inspect / clean / grease / adjust the mast.
40
BREAKDOWN
24V
Preliminary verifications :
This movement is the only one affected
(Jib lowering function is operational).
No external lead.
Battery charged correctly.
Battery connections in good condition.
The machine is on flat and horizontal ground.
< 24V
Check / repair the coil connector.
Check / repair the loom PC0193.
Other
Replace the coil.
Incorrect
Clean and / or replace the seals
and/or replace the valve.
Incorrect
Clean and / or replace the seals
and/or replace the valve.
Incorrect
Clean and/or replace the valve.
Incorrect
Clean and/or replace the valve.
Incorrect
Clean and/or replace the valve.
Incorrect
Clean and/or replace the seals
and/or replace the relief valve.
Incorrect
Clean and/or replace the seals
and/or replace the valve.
Stuck
Clean and/or replace the regulator.
Toucan 861
III-3
Models
Updated 04-06

Advertisement

Table of Contents
loading

Table of Contents