SYMPTOMS
Unit not steaming
Door leaks
Water accumulates in
compartment
Water not being supplied to
generator
Steam is exiting from
under unit

TROUBLESHOOTING

POSSIBLE CAUSES
Gas supply is off
Power cord is unplugged
Power switch is off
Water supply is off
Burner control goes into 100%
lockout
Damaged door gasket
High Water Pressure
Plugged drain or screen
Drain clogged
Not leveled properly
Water supply valve is off
Water pressure low
Water filter is plugged
Generator pressure is too high
— 20 —
REMEDY
Turn on gas supply
Plug in power cord.
Press power switch on
Turn on water supply
Shut off the power, wait 5
minutes, then turn power back on
to restart ignition.
If symptom persists, contact your
Authorized Vulcan Servicer.
Check door gasket for damage.
Verify water pressure is between
20-60 psi.
Verify drain plumbing.
If symptom persists, contact your
Authorized Vulcan Servicer.
Clear compartment cavity screen.
If symptom persists, contact your
Authorized Vulcan Servicer.
Unclog drain.
Level per instructions in this
manual.
High water pressure drain
installation.
Turn valve on.
Check water supply pressure.
Refer to water filter manual.
If symptom persists, contact your
Authorized Vulcan Servicer.
Contact your Authorized Vulcan
Servicer.