ROUND COUNTERTOP TILTING BRAISING PANS (16 GALLON) Gas and Electric - TROUBLESHOOTING
Certain procedures in this section require electrical test or measurements while power is
applied to the machine. Exercise extreme caution at all times and follow Arc Flash procedures.
If test points are not easily accessible, disconnect power and follow Lockout/Tagout
procedures, attach test equipment and reapply power to test.
SYMPTOM
Unit will not heat (temperature light
off).
Pan difficult to tilt.
Cooking temperature incorrect.

TROUBLESHOOTING

ALL MODELS

1.
Check incoming voltage.
2.
Control thermostat not turned on or remains open.
3.
Power switch malfunction.
4.
High limit thermostat open.
5.
Heating element inoperative (electric model).
6.
Heater contactor(s) malfunction (electric model).
1.
Dirt in Oilite bearings, causing it to bind. See BEARINGS.
NOTE: Never grease or oil the pivot bearings, as this may cause
problems with tilting. Bearings are Oilite and never require lubrication.
1.
Thermocouple not secured properly to bottom of pan.
2.
Thermocouple lead wire(s) pulled loose from connection or damaged.

GAS MODELS ONLY

Page 25 of 26
POSSIBLE CAUSES
F24643 (1217)