Operation Manual Shodex RSpak NN-814
Shodex™ RSpak™ NN-814
Europe, Middle East, Africa, Russia
www.shodex.de
All manuals and user guides at all-guidesbox.com
Operation Manual
Sales Office:
Showa Denko Europe GmbH
Shodex Business
Konrad-Zuse-Platz 3
81829 Munich
Germany
Version 211102E
Technical Support:
info@shodex.de
+49 (0)89 / 93 99 62 37
Quotes and Orders:
order@shodex.de
+49 (0)89 / 93 99 62 34

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Shodex RSpak NN-814 and is the answer not in the manual?

Questions and answers

Summary of Contents for Showa Denko Shodex RSpak NN-814

  • Page 1 All manuals and user guides at all-guidesbox.com Operation Manual Shodex RSpak NN-814 Version 211102E Operation Manual Shodex™ RSpak™ NN-814 Sales Office: Technical Support: Showa Denko Europe GmbH info@shodex.de Shodex Business +49 (0)89 / 93 99 62 37 Konrad-Zuse-Platz 3 81829 Munich...
  • Page 2 All manuals and user guides at all-guidesbox.com Operation Manual Shodex RSpak NN-814 Version 211102E Operation Manual Shodex™ RSpak™ NN-814 (Please read this manual carefully to achieve the best and consistent column performance for a long time) Important Handling Instructions Caution! •...
  • Page 3 All manuals and user guides at all-guidesbox.com Operation Manual Shodex RSpak NN-814 Version 211102E Usable conditions Temperature Flow Rate (mL/min) Maximum Pressure Product Name Range Range (°C) (MPa) (Per Column) Recommended Maximum 2 - 12 10 - 60 RSpak NN-814 0.5 - 1.0...
  • Page 4 All manuals and user guides at all-guidesbox.com Operation Manual Shodex RSpak NN-814 Version 211102E (2) Filter the sample solution using disposable 0.45 μm filter to prevent the column from clogging or deteriorating. (3) Recommended sample injection volume is 50 μL per column.
  • Page 5 All manuals and user guides at all-guidesbox.com Operation Manual Shodex RSpak NN-814 Version 211102E temperature return to room temperature before stopping the pump. If the pump was stopped while the eluent inside the column was still hot, as the eluent temperature decreases, its volume also decreases.
  • Page 6 All manuals and user guides at all-guidesbox.com Operation Manual Shodex RSpak NN-814 Version 211102E Column Inspection Inspection method is described in the Certificate of Analysis (CoA). Theoretical Plate Number (N) and Asymmetry Factor (Fas) were calculated using the below equations.
  • Page 7 11. Warranty (Version 4) (1) Showa Denko K.K. warrants that the Shodex™ product, at the time of delivery to the user, will conform to the specification of the attached CERTIFICATE OF ANALYSIS, if the Shodex product is used in accordance with the attached operating manual.