Showa Denko Shodex SUGAR SP0810 8C Operation Manual

Advertisement

Operation Manual Shodex SUGAR SP0810 8C
Shodex™ SUGAR™ SP0810 8C
Europe, Middle East, Africa, Russia
www.shodex.de
Operation Manual
Sales Office:
Showa Denko Europe GmbH
Shodex Business
Konrad-Zuse-Platz 3
81829 Munich
Germany
Version 211015E
Technical Support:
info@shodex.de
+49 (0)89 / 93 99 62 37
Quotes and Orders:
order@shodex.de
+49 (0)89 / 93 99 62 34

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Shodex SUGAR SP0810 8C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Showa Denko Shodex SUGAR SP0810 8C

  • Page 1 Operation Manual Shodex SUGAR SP0810 8C Version 211015E Operation Manual Shodex™ SUGAR™ SP0810 8C Sales Office: Technical Support: Showa Denko Europe GmbH info@shodex.de Shodex Business +49 (0)89 / 93 99 62 37 Konrad-Zuse-Platz 3 81829 Munich Quotes and Orders: Europe, Middle East, Africa, Russia Germany order@shodex.de...
  • Page 2 Operation Manual Shodex SUGAR SP0810 8C Version 211015E Operation Manual Shodex™ SUGAR™ SP0810 8C (Please read this manual carefully to achieve the best and consistent column performance for a long time) Important Handling Instructions Caution! • Please consult the Safety Data Sheet (SDS) for the reagents and solvents used with the columns and understand their proper handling methods to prevent potential health hazard or death from occurring.
  • Page 3: Eluent Preparation

    Operation Manual Shodex SUGAR SP0810 8C Version 211015E Usable conditions Flow Rate (mL/min) Temperature (°C) Maximum Pressure Product Name (MPa) (Per Column) Recommended Maximum Recommended Maximum SUGAR SP0810 8C 0.5 - 1.0 70-85 SUGAR SP-G 6B 70-85 When analyzing under 40°C, set the flow rate at less than 0.5 mL/min to reduce the column load.
  • Page 4: Column Installation

    Operation Manual Shodex SUGAR SP0810 8C Version 211015E (5) When a sample contains cations other than lead ions (the pretreated sample after neutralization), remove them by using a cation exchange resin. (6) When a sample contains protein or lipid, make sure to remove them prior to the injection. Proteins may be removed by ultrafiltration or by adding acid or acetonitrile.
  • Page 5: Column Storage

    Operation Manual Shodex SUGAR SP0810 8C Version 211015E • If the column was used at an elevated temperature, let the column temperature return to room temperature before stopping the pump. If the pump was stopped while the eluent inside the column was still hot, as the eluent temperature decreases, its volume also decreases.
  • Page 6 11. Warranty (Version 4) (1) Showa Denko K.K. warrants that the Shodex™ product, at the time of delivery to the user, will conform to the specification of the attached CERTIFICATE OF ANALYSIS, if the Shodex product is used in accordance with the attached operating manual.

This manual is also suitable for:

Shodex sugar sp-g 6bF6378106F6700081

Table of Contents