Operation Manual Shodex RSpak DM-614
Shodex™ RSpak DM-614
Europe, Middle East, Africa, Russia
www.shodex.de
Operation Manual
Sales Office:
Showa Denko Europe GmbH
Shodex Business
Konrad-Zuse-Platz 3
81829 Munich
Germany
Version 210707E
Technical Support:
info@shodex.de
+49 (0)89 / 93 99 62 37
Quotes and Orders:
order@shodex.de
+49 (0)89 / 93 99 62 34

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Shodex RSpak DM-614 and is the answer not in the manual?

Questions and answers

Summary of Contents for Showa Denko Shodex RSpak DM-614

  • Page 1 Operation Manual Shodex RSpak DM-614 Version 210707E Operation Manual Shodex™ RSpak DM-614 Sales Office: Technical Support: Showa Denko Europe GmbH info@shodex.de Shodex Business +49 (0)89 / 93 99 62 37 Konrad-Zuse-Platz 3 81829 Munich Quotes and Orders: Europe, Middle East, Africa, Russia Germany order@shodex.de...
  • Page 2 Certificate of Analysis (CoA) are matching and correct. Introduction Thank you for purchasing the Shodex™ product. Shodex RSpak DM-614 is a polymer-based reversed phase chromatography column. It can be used in a wide pH range from acidic to alkaline (pH 2 - 10).
  • Page 3 Operation Manual Shodex RSpak DM-614 Version 210707E Usable Conditions Flow Rate (mL/min) Maximum Pressure Temperature Product Name pH Range (MPa) (Per Column) Range (°C) Recommended Maximum RSpak DM-614 0.5 - 1.0 2 - 10 RT – 60°C RSpak DM-G 4A...
  • Page 4 Operation Manual Shodex RSpak DM-614 Version 210707E (4) For the samples containing proteins, remove the proteins prior to the sample injection. Note • Use of guard column is recommended to protect the analytical column. Column Usage Procedure 7.1. HPLC System Preparation Wash entire LC system prior to the column installation, including all flow-lines and sample loop by switching the valve, and then replace the washing solution with the eluent to be used.
  • Page 5 Operation Manual Shodex RSpak DM-614 Version 210707E 7.3. Solvent Exchange (1) When replacing the solvent, start the system at less than 0.3 ml/min. Recommended solvent volume to introduce at each step is 3 to 5 times of the column volume.
  • Page 6 3-3 If the Shodex product is disposed of 3-4 If the Shodex product is resold by the user without giving prior written notice to Showa Denko K.K. 3-5 If the performance of the Shodex product is not conform to the specification of the attached CERTIFICATE OF ANALYSIS due to any of the reasons below: a.