Summary of Contents for Showa Denko Shodex Shodex IC SI-36 4D
Page 1
Operation Manual Shodex IC SI-36 4D Version 200603E Operation Manual Shodex™ IC SI-36 4D Sales Office: Technical Support: Showa Denko Europe GmbH info@shodex.de Shodex Business +49 (0)89 / 93 99 62 37 Konrad-Zuse-Platz 3 81829 Munich Quotes and Orders: Europe, Middle East, Africa, Russia Germany order@shodex.de...
Page 2
Operation Manual Shodex IC SI-36 4D Version 200603E Operation Manual Shodex IC SI-36 4D (Please read this manual carefully to achieve the best and consistent column performance for a long time) Important Handling Instructions Caution! • Please consult the Safety Data Sheet (SDS) of reagents and solvents used with the column and understand their proper handling methods to prevent potential health hazards or death from occurring.
Page 3
Operation Manual Shodex IC SI-36 4D Version 200603E Usable Conditions Maximum Temperature Range (°C) Flow Rate (mL/min) Product Pressure (MPa) Name Range Recommended Maximum Recommended Range (Per Column) IC SI-36 4D 3 - 14 20 - 60 IC SI-90G 3 - 14 20 - 60 Usable solvents are listed below (1) In general, either potassium hydroxide or sodium hydroxide is used.
Page 4
Operation Manual Shodex IC SI-36 4D Version 200603E • A drastic change in the eluent compositions may remove substances adsorbed on the system and they may enter and deteriorate the column. 6.2. Column Installation (1) Connect the column to LC system by following the “flow direction arrow” () indicated on the name tag.
Page 5
Operation Manual Shodex IC SI-36 4D Version 200603E • Always use freshly prepared solvents. Solvents stored for a long time may have changed their compositions and may influence elution patterns and/or damage the column. • If using a manually prepared eluent, keep the eluent in a solvent reservoir with a carbonate trap cartridge.
Page 6
Operation Manual Shodex IC SI-36 4D Version 200603E Attention! • Never allow inside of the column to dry. It can damage the column. • When replacing the in-column solvent with shipping solvent, detach the suppressor before introducing the shipping solvent to the column. •...
Page 7
3-3 If the Shodex product is disposed of 3-4 If the Shodex product is resold by the user without giving prior written notice to Showa Denko K.K. 3-5 If the performance of the Shodex product is not conform to the specification of the attached...
Need help?
Do you have a question about the Shodex Shodex IC SI-36 4D and is the answer not in the manual?
Questions and answers