Setup; Fuse Replacement; Power Input; Connecting The Fixtures - Blizzard Lighting Motif Risplendi 150 Manual

Table of Contents

Advertisement

3. SETUP

Fuse Replacement

Remove the fuse holder from of its housing. Take out the damaged fuse from its
holder and replace with exact same type of fuse.
Power Inputs
This fixture comes with a powerCON® TRUE1™ compatible power input and a
3-wire power terminal block connector located under the "Int. Power In" cover
plate on the rear of the fixture that can be used for hardwiring power.
Depending on which method you use, adjust the external/internal power switch
on the back of the unit to select the proper input source.
Use the table below for reference when using the bare wire:
Connection
AC Live
AC Neutral
AC Ground

Connecting the Fixtures

Fixtures on a serial data link must be daisy chained in one single line. Also,
connecting more than 32 fixtures on one serial data link without the use of a
DMX optically-isolated splitter may result in deterioration of the signal.
Data/DMX Cabling
To link fixtures together you'll need data cables. You should use data-grade
cables that can carry a high quality signal.
The data cable should have the following characteristics:
• 2-conductor twisted pair plus a shield
• Maximum capacitance between conductors – 30 pF/ft.
• Maximum capacitance between conductor & shield – 55 pF/ft.
• Maximum resistance of 20 ohms / 1000 ft.
• Nominal impedance 100 – 140 ohms
Motif™ Risplendi 150 - Rev. A
Before replacing the fuse, disconnect the power cord.
ALWAYS replace it with the same type and rating.
Wire (U.S.)
Black
White
Green/Yellow
Page 7
Wire (Europe)
Brown
Blue
Green/Yellow
Screw Color
Yellow or Brass
Silver
Green
© 2023 Blizzard Lighting, LLC