11 | Analog and Frequency Inputs
11.2.3 Configuring a generic nonlinear sensor
58 / 136
Available measurements for channel:
Measurement label
raw_name
raw_name_fi
name
name_fi
Note
Working with automatically created measurement sheets is explained in chapter 'Setting
up an online measurement [} 73]'.
Example: Thermistor 5 kOhm
– From sensor data sheet - resistance values over temperature:
– The sensor has a nonlinear behavior
– Use characteristic curve for linearization
– Input voltage is the ratio between pull-up resistor and thermistor
+5V
Pin
3 kOhm
Thermistor
1.
Click 'Measurement Sources' in the Toolbox.
2.
To expand the list of 'I/O Channels', click on '+' in the VCU MS 50.4 Project Tree.
3.
Drag the "Characteristic Curve" analogue signal source from the Toolbox and drop it
on the desired analogue input channel in the VCU MS 50.4 Project Tree.
Vehicle_Control_Unit_VCU_MS_50.4_Manual
Function
mV value of sensor
filtered mV value of sensor
physical value of sensor
filtered physical value