Bosch MS 50.4 Manual page 56

Vehicle control unit
Table of Contents

Advertisement

11 | Analog and Frequency Inputs
11.2.2 Configuring a generic linear sensor
56 / 136
Example: Acceleration sensor 5 g
– From sensor data sheet - operating characteristics:
– Sensitivity 400 mV/g, Offset 2,500 mV
– The sensor has a linear output signal with sensitivity and offset
1.
Click on 'Measurement Sources' in the Toolbox.
2.
To expand the list of 'I/O Channels', click on '+' in the VCU MS 50.4 Project Tree.
3.
Drag the "Sensitivity/Offset" analog signal source from the Toolbox and drop it on the
desired analog input channel in the VCU MS 50.4 Project Tree. A "Sensitivity/Offset
Wizard" opens.
4.
To activate the internal pullup-resistor, check the box. The internal pullup-resistor is
used to get a 5 V signal at the analog channel of the VCU MS 50.4. It allows you to
use a push-button. The fixed value of the internal pullup-resistor is 3,010 Ohm. If us-
ing an additional external pullup-resistor, set up the overall resistance.
5.
Click 'Next' when done.
The second part of the "Sensitivity/Offset Wizard" opens.
Vehicle_Control_Unit_VCU_MS_50.4_Manual
Bosch Motorsport

Advertisement

Table of Contents
loading

Table of Contents