Open closing handle
to get access to hose
connection.
96
R E P A I R S
8.7.2 Replacing compact brewing unit
•
Use a pair of pointed pliers to remove connector clip (34) and hose (29) with Oring
(36).
•
Use Torx screwdriver TX10 to loosen 4 screws (40).
•
After removal of compact brewing unit (14), release 2 latches with screwdriver and
remove steam cover (13).