Autoscale - TECPEL OS Series User Manual

Handheld digital storage oscilloscope & multimeter
Table of Contents

Advertisement

OS Series Handheld DSO & DMM
—Cursor 2
Press ▲ (yellow) or ▼ (yellow) to see V1 move up and down and the panel will display the
voltage value match V1 and Channel 1 Zero; Press ◄ (yellow) or ► (yellow) to see V2 move up
and down and panel will display the voltage value match V2 to Channel 1 Zero. LCD panel also
display the absolute value of V1-V2.
Now, you can see a screen that looks like the following figure 56.

8.12 Autoscale

The function is applied to follow-up signals automatically even if the signals change at any time.
Autoscale enables the instrument to set up trigger mode, voltage division and time scale
automatically according to the type, amplitude and frequency of the signals.
The menu is as follows:
Function menus
Autoscale
Mode
HORI—VERT
Figure 56: Cursor range measurement
Settings
Description
OFF
Turn off Autoscale
Turn on Autoscale
ON
Horizontal
Follow-up and adjust horizontal scale without changing
vertical setting
Vertical
Follow-up and adjust vertical scale without changing
horizontal setting
Follow-up and adjust the vertical and horizontal settings.
8-Advanced Function of Oscilloscope
61