General Descrip5on
1.
This is a 3 5/6 digital mulDmeter with high stability and performance. It uses a LCD with
20mm high figure, which makes the reading clearer and the operaDon more convenient.
It can test DCV, ACV, DCA, ACA, resistance, capacitance, frequency, NCV, duty cycle,
temperature, diode, and conDnuity. This meter also designed with funcDons including
unit symbol display, data hold, lighDng, auto range, auto power off and warning
funcDons. To assure high accuracy and resoluDon, it adopts integrated circuit 8-bit
microprocessor and a dual integral A/D conversion as LCD driver, giving high resoluDon
and high accuracy. It is an ideal tool for labs, factories and radio-technology.
2. Safety Instruc5ons
The instrument is designed in compliance with IEC1010 standard (safety standard issued
by InternaDonal Electro technical Commi]ee). Please read the following safety
instrucDons before operaDon.
2.1 Check the connecDon and insulaDon of test leads to avoid electric shock.
2.2 To avoid electric shock and damage to the meter, do not input voltage exceeding
rated value.
2.3 When measuring voltage higher than DC 60V or AC 40V, please be careful and avoid
electric shock.
2.4 Select correct funcDon and range to avoid wrong operaDon.
2.5 Move the test leads away from test points when switching to other funcDon.
2.6 Don't input voltage in current terminal.
2.7 Don't make any modificaDon to the circuit. It may damage the meter or jeopardize
safety.
2.8 Safety symbols:
" " High voltage, " " GND, " " Dual insulaDon, " " Refer to manual, " " Low
ba]ery indicaDon.
3. Features
3.1 General CharacterisDcs
3.1.1 Display: LCD;
3.1.2 Max display: 6000 (3 5/6 digits, automaDc polarity, and unit symbol display);
3.1.3 Measurement method: Analog to digital converter (in micro processor ADC+MCU);
3.1.4 Sampling rate: approx.3 Dmes/sec.
3.1.5 Over-range display: "OL" displayed.
3.1.6 Low ba]ery indicator: " "
3.1.7 Working environment: (0~40)℃, relaDve humidity: <80%;
3.1.8 Store condiDon: (-10~50)℃, relaDve humidity: <80%
3.1.9 Ba]ery: 2 pieces 1.5V ba]ery ("AAA" 7# ba]ery);
3.1.10 Dimension: 140×72×37mm (length x width x height);
3.1.11 Weight: approx. 195g (including ba]ery);
3.1.12 Accessories: test leads, TP01 thermocouple, user manual, holster, gip box, and
2*1.5V ba]eries.
3.2 Technical Features
3.2.1 Accuracy: ± (a% × reading + digits). To assure accuracy, the ambient temperature
should be (23±5) ℃, relaDve humidity <75%. One year accuracy is guaranteed since
producDon date.
3.2.2 DC Voltage(DCV)
Range
Accuracy
600mV
6V
±(0.5%+4)
60V
600V
±(1.0%+4)
Input impedance: at 200mv range >40MΩ, at other ranges is 10MΩ.
Overload protecDon: 600V DC/AC rms.
3.2.3. AC Voltage(ACV)
Range
Accuracy
6V
±(0.8%+6)
60V
600V
±(1.0%+6)
Resolution
0.1mV
1mV
10mV
100mV
Resolution
1mV
10mV
100mV

Advertisement

loading

Summary of Contents for TECPEL DMM-136A

  • Page 1 3.1.2 Max display: 6000 (3 5/6 digits, automaDc polarity, and unit symbol display); DMM-136A DIGTAL MULTIMETER Opera5on Manual 3.1.3 Measurement method: Analog to digital converter (in micro processor ADC+MCU); CONTENTS 3.1.4 Sampling rate: approx.3 Dmes/sec. GENERAL DESCRIPTION …………………………… 3.1.5 Over-range display: “OL” displayed.
  • Page 2: Resistance(Ω

    Input impedance: at ranges is 10MΩ. Frequency response: 10A range: 40~100Hz, other ranges: 40~400Hz. Overload protecDon: 600V DC/ AC rms. Frequency response: at 600V range: (40~1000)Hz, at other ranges: (40~2000)Hz 3.2.6 Resistance(Ω) Displaying: True RMS response (calibraDon based on sine wave RMS) Range Accuracy Resolution...
  • Page 3 10Hz 0.01Hz 100Hz 0.1Hz 1000Hz 10kHz ±(0.5%+4) 10Hz 100kHz 100Hz Number Feature DescripDon 1MHz 1kHz △ Relative (REL) mode is active 60MHz 10kHz Data Hold is acDve. Input sensiDvity: 0.7V rms. Overload protecDon: 250V DC/AC peak value. Indicates negaDve readings. DC voltage or current measurement.
  • Page 4 Under (Diode/ConDnuity) range, press SELECT key can choose diode test) or Switch DescripDon (conDnuity test). Under temperature ranges, press SELECT key to choose Degrees posiDon Celsius or Degrees Fahrenheit. Under ACV ranges, press SELECT key to switch AC voltage measurement. Press SELECT key to switch between frequency/ duty cycle between Frequency or Duty Cycle measurement.
  • Page 5 point connected by the red test lead. is inserted into). Current exceeding rated value will damage the fuse, and may cause NOTE: damage to the circuit of meter. 1) If LCD display “OL” under manual range, it means it is over range, now you need to select a higher range.
  • Page 6: Capacitance Measurement

    4.7 CAPACITANCE MEASUREMENT 1) Even if there is no voltage indicaDon, there may be voltage on the circuit. Do not rely 4.7.1 Insert the black lest lead in “COM” terminal and the red one in “VΩmA” terminal; on NCV detector as the only way to detect voltage. 4.7.2 Turn the rotary to switch to “...
  • Page 7: Maintenance

    Fatult SoluDon 5. MAINTENANCE ■ Turn on the power; This meter is a precise instrument. Any modificaDon to the circuit is not allowed. No reading on LCD ■ Release the HOLD key; NOTE: ■ Replace battery. Don’t input the voltage value higher than 600V DC or AC rms.