TECPEL OS Series User Manual page 18

Handheld digital storage oscilloscope & multimeter
Table of Contents

Advertisement

OS Series Handheld DSO & DMM
Description:
1.
Battery electric quantity indicating symbols, including
2.
Auto measurement window 1, in which "f "means frequency, "T" means cycle, "V" means
the average value, "Vp" the peak-peak value ,"Vk" the root-mean-square value,. "Ma" the
maximum amplitude value, "Mi" the minimum amplitude value, "Vt" the Voltage value of
the waveform's flat top value, "Vb" the Voltage value of the waveform's flat base, "Va" the
amplitude value, "Os" the overshoot value, "Ps" the Preshoot value, "RT" the rise time value,
"FT" the fall time value, "PW" the +width value, "NW" the -Width value, "+D" the +Duty
value, "-D" the -Duty value, "PD" the DelayA B
value.
3.
Auto measurement window 2.
4.
The pointer indicates the horizontal triggering position.
5.
This reading gives the Time Difference between the horizontal triggering position and the
screen centerline. It reads zero when the pointer is in the center of the screen.
6.
The trigger state indicates the following information.
Auto: The oscilloscope is working in the automatic mode and displaying the waveform
under the non-trigger state.
Trig'd: The oscilloscope has detected a trigger and collecting the information generated
after the trigger.
Ready: All pre-triggered data have been captured and the oscilloscope has been ready to
receive trigger signals.
Scan: The oscilloscope can gather and display the waveform data continuously in scanning
mode.
Stop: The oscilloscope has stopped collecting the waveform data.
7.
Red and blue index display triggers vertical position during alternate trigger and triggers
index become green when it reaches edge trigger or video trigger.
8.
A hidden-style menu: With the MENU key pressed, you can view or hide the menu.
9.
Menu setting options: There are different setting options for different menus.
10. It reads the value of trigger voltage level.
11. The display shows the trigger signal source.
12. The reading gives the value of primary time base.
13. These graphics present the coupling modes of channel 2(CH2). The graphic "~" indicates
AC, the graphic "-" indicates DC, the graphic "
14. This reading shows the vertical Voltage Unit Scale of CH2.
,
,
and .
value and "ND" the DelayA B
" indicates GND.
13
6-Using the Oscilloscope

Advertisement

Table of Contents
loading

This manual is also suitable for:

Os-1022Os-2062Os-3102

Table of Contents