    Table of Contents Chapter Title Page Before You Start Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols Using The Testing Tool Reading the screen The Meter Structure Functional Buttons Making Measurements A. Scope Mode i. Setting up the Sleep Mode, Contrast, Beep ii.
  • Page 3 OS-81B Oscilloscope multimeter Table of Contents Chapter Title Page vii. Measuring Capacitance Using Software Maintenance The Test Tool A. General Service B. Replacing the Fuses C. Replacing the Battery Specifications Safety and Compliances Physical Specifications General Specifications (Digital Multimeter) General Specifications (Scope)
  • Page 4 Table of Contents Chapter Title Page H. Frequency and Duty Cycle % I. Capacitance...
  • Page 5 OS-81B Oscilloscope multimeter List of Tables Table Title Page Unpacking Inspection International Electrical Symbols Reading the Screen Functional Buttons...
  • Page 6 List of Tables Figure Title Page Meter Structure Functional Buttons Waveform Display Voltages Measurement µ A Range Measurement mA Range Measurement 10A Range Measurement Resistance Measurement Diode Test Continuity Test Frequency / Duty Cycle Measurement 3-10 Capacitance Measurement Fuse Replacement Battery Replacement...
  • Page 7: Before You Start

    Oscilloscope multimeter Chapter 1 Before You Start Overview bandwidth TECPEL OS-81B : 8MHz, real-time sample This Operating Manual covers information on safety rate 40MS/s with peak rate sampling process can catch and cautions. Please read the relevant information up pulse industrial signal. It can measure AC/DC engine,...
  • Page 8: Unpacking Inspection

    Unpacking Inspection Open the package case and take out the Meter. Check the items shown on Table 1-1 carefully to see any missing or damaged part: Table 1-1. Unpacking Inspection Item Description English Operating Manual 1 piece USB interface cable 1 piece CD-ROM (Installation Guide &...
  • Page 9: Safety Information

    OS-81B Oscilloscope multimeter International electrical symbols used on the Meter and Safety Information in this Operating Manual are explained on page 10. This Meter complies with the standards IEC61010 safety measurement requirement: in pollution degree 2, Rules For Safe Operation overvoltage category (CAT.
  • Page 10 connecting the Meter to the circuit. shock or damages to the Meter. Replace the battery as soon as the battery The rotary switch should be placed in the right   position and no any changeover of range shall indicator appears.
  • Page 11: International Electrical Symbols

    OS-81B Oscilloscope multimeter  Under the influence of Radiated Radio-Frequency International Electrical Symbols Electromagnetic Field phenomenon, the captioned Symbols used on the Meter and in this manual are model have a 20% measurement error, it will be explained in Table1-2.
  • Page 12: Using The Testing Tool

    Chapter 2 Using the Testing Tool Reading the Screen The screen displays the menu that provides the following choices available: Table 2-1. Reading the Screen Table 2-1. Reading the Screen Display Description Display Description RANG Decrease a range Contrast The degree of contrast BASE Increase a time base Auto Off...
  • Page 13: The Meter Structure

    OS-81B Oscilloscope multimeter The Meter Structure The Figure 2-1 shows the Meter structure. 1. USB Terminals 2. LCD Display 3. Functional Buttons 4. Rotary Switch 5. Power adaptor Input Terminals 6. 10A Input Terminal 7. mA µ A Input Terminals 8.
  • Page 14: Functional Buttons

    Functional Buttons Table 2-2. Functional Buttons The buttons activate features that augment the function selected with the rotary switch. The buttons are shown Description Buttons in Table 2-2. Software functional buttons, details F1, F2, please refer to the below. F3 and F4 Under scope mode, Press Range Range button to switch between DC and AC...
  • Page 15: Waveform Display

    OS-81B Oscilloscope multimeter Table 2-2. Functional Buttons Description Buttons To switch between waveform display Mode (scope mode) and digital reading (multimeter mode). This button is only valid when under voltage, frequency, currents mode. Press Set button to set the auto power...
  • Page 16: Making Measurements

    Chapter 3 Making Measurement Introduction Chapter 3 explains how to make measurements. Based on the working environment to set up sleep mode, contrast, beep You could turn the Meter off by turning to OFF position Press Set button to set the auto power off, display or set up the sleep mode from 1-30 minutes.
  • Page 17 OS-81B Oscilloscope multimeter F2: Set the Display Backlight F4: Set the beeps features, it can only be used under BK Light ENTER resistance, diode and continuity measurement. Beep ENTER The brightness level from 0 to 31. Press F4 to confirm, save and return. Press functional buttons to exit, the setting is kept, but will not save.
  • Page 18: Scope Mode

    Press Range to switch between DC and AC measurement. Turn the rotary switch to ACV, DCV, Hz, ACA or DCA When the frequency and amplitude of a waveform range, the Meter displays digital reading (Multimeter is unknown, press Auto : mode).
  • Page 19 OS-81B Oscilloscope multimeter Y-axis adjustment: Press Range button under scope increase the number of periods mode, the corresponding functional button: decrease the number of periods. Move Move Rang Rang trigger point move left trigger point right move move up the waveform...
  • Page 20: Trigger Function

    10 location) F4: confirm Press Trig button under scope mode, the corresponding function buttons: When saving the data, it will overwrite the current Trig Trig Auto/Norm/Shot Slop Rrise/Fall data in the location no matter that location has data or not. If you recall the location has no data, the meter will appear error message, you need to press HOLD F1: move the trigger level up...
  • Page 21: Digital Multimeter Mode

    OS-81B Oscilloscope multimeter B. Digital Multimeter Mode be returned to working mode to carry out measurement. Warning In order to have more accurate waveform, user can buy an optional BNC probe and scope probe to decrease To avoid harms to you or damages to the Meter signal attenuates.
  • Page 22 LCD. When voltage measurement has been completed, disconnect the connection between the testing leads and the circuit under test and remove testing leads away from the input terminals of the Meter. Figure 3-2. Voltages Measurement OS-81B...
  • Page 23: Measuring Currents

    OS-81B Oscilloscope multimeter Warning If the fuse burns out during measurement, the Meter may be damaged or the operator himself may be hurt. To avoid possible damage to the Meter or to the equipment under test, check the Meter’s fuses before measuring current.
  • Page 24 4. The measured value shows on the display. 5. Press MODE button to toggle between Multimeter mode and Scope mode. 6. Press F1 to toggle between AC and DC current measurement. Figure 3-3. µA Range Measurement OS-81B...
  • Page 25 OS-81B Oscilloscope multimeter 1. Insert the red test lead into the µA mA terminal and black test lead into the COM terminal. To measure ACmA or DcmA currents, set up the 2. Set the rotary switch to mA . Meter as Figure 3-4 and proceed as follows: 3.
  • Page 26 4. The measured value shows on the display. 5. Press MODE button to toggle between Multimeter mode and Scope mode. 6. Press F1 to toggle between AC and DC current measurement. Figure 3-5. 10A Range Measurement OS-81B...
  • Page 27 OS-81B Oscilloscope multimeter Note When measuring current, the corresponding functional buttons: After changing the measurement mode, the AC / DC Rang Rang autoranging will be off automatically and the AUTO will be disappeared at the bottom left of the LCD.
  • Page 28: Measuring Resistance

    Warning OS-81B To avoid possible damages to the Meter or to the devices under test, disconnect circuit power and discharge all the high-voltage capacitors before measuring resistance. To measure resistance, set up the Meter as shown in Figure 3-6 and follow the following procedure:...
  • Page 29: Resistance Measurement

    OS-81B Oscilloscope multimeter 1. Insert the red test lead into the Ω terminal and the Note black test lead into the COM terminal. When measuring low resistance, the test leads can 2. Set the rotary switch to Ω add 0.1Ω to 0.2Ω of error to resistance measurement.
  • Page 30: Testing Diodes

    Use the diode test to check diodes, transistors, and other semiconductor devices. The diode test sends a current through the semicondutor junction, then measure the voltage drop across the junction. A good silicon junction drops between 0.5V and 0.8V Figure 3-7. Diode Test OS-81B...
  • Page 31 OS-81B Oscilloscope multimeter 1. Insert the red test lead into the Ω terminal and the Note black test lead into the COM terminal. Connect the test leads to the proper terminals as Ω 2. Set the rotary switch to said above to avoid error display.
  • Page 32: Testing For Continuity

    60V DC or 42V rms AC. To avoid possible damages to the Meter or to the devices under test, disconnect circuit power and discharge all the high-voltage capacitors before measuring continuity. Figure 3-8. Continuity Test OS-81B...
  • Page 33 OS-81B Oscilloscope multimeter 1. Insert the red test lead into the W terminal and the Note black test lead into the COM terminal. When continuity testing has been completed, 2. Set the rotary switch to Ω disconnect the connection between the testing leads 3.
  • Page 34: Measuring Frequency / Duty Cycle

    Scope mode. 6. Press F1 to toggle between frequency and duty cycle measurement. When measuring frequency and duty cycle, the corresponding functional buttons: Freq/Duty F1: toggle between frequency and duty cycle Figure 3-9. Measuring Frequency / Duty Cycle OS-81B...
  • Page 35 OS-81B Oscilloscope multimeter Note The requirement of Input amplitude “a” is as follows: When 1MHz: 300 mV 30Vrms; 1MHz: 600 mV 5Vrms It is normal to have few seconds run time when switch from other functions to these functions. When Hz or duty cycle measurement has been...
  • Page 36: Measuring Capacitance

    To measure capacitance, set up the Meter as shown in Figure 3-10 and proceed as follows: Warning To ensure accuracy, the Meter inside is discharged against the tested capacitor To avoid damage to the Meter or to the equipment under test, disconnect circuit power and discharge all high-voltage capacitors before measuring capacitance.
  • Page 37 OS-81B Oscilloscope multimeter Insert the red test lead into theterminal and the When measuring capacitance, the corresponding black test lead into the COM terminal. functional buttons: Set the rotary switch to measurement mode, the Capacity Meter may display a fixed reading which is a internal distributed capacitor value.
  • Page 38: Using Software

    Chapter 4 Using Software When using the Software, please refer to the Installation Guide of the included CD-ROM.
  • Page 39: Maintenance The Test Tool

    OS-81B Oscilloscope multimeter Chapter 5 Maintaining The Test Tool This chapter provides basic maintenance information high temperature, explosive, inflammable and strong including battery and fuse replacement instruction. magnetic field. Warning Do not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration, performance test, and service information.
  • Page 40: Replacing The Fuses

    B. Replacing the Fuses Follow Figure 5-1 and proceed as follows to replace the Meter’s fuse: Turn the rotary switch to OFF and remove all  connections from the terminals. Remove the screw from the battery compartment,  and separate the battery compartment from the case bottom.
  • Page 41: Replacing The Battery

    OS-81B Oscilloscope multimeter C. Replacing the Battery Warning To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the battery indicator “ ” appears. Make sure the test leads are disconnected from the circuit being tested before opening the case bottom.
  • Page 42: Specifications

    Chapter 6 Specifications Safety and Compliances Maximum Voltage between any Terminal and Refer to different range input protection voltage Grounding Certification Compliances IEC 61010 CAT. II 1000V, CAT.III 600V overvoltage and double insulation standard Fused Protection for mA input terminal: F0.5AH/250V, ø5×20mm Fused Protection for 10A input terminal: F10AH/250V, ø5×20mm...
  • Page 43: Physical Specifications

    OS-81B Oscilloscope multimeter Physical Specifications Digital: 3999 counts on display ; updates 2-3 times / second. Display (LCD) C~40 C (32 F~104 Operating Temperature C~50 C (14 F~122 Storage Temperature 75% @ 0 C~40 Relative Humidity 0% @ -10 C~50 Operating: 2000m;...
  • Page 44: General Specifications (Digital Multimeter)

    General Specifications ( Digital Multimeter) When it is under Multimeter mode, you could select either auto or Range manual ranging. Auto, negative polarity displays “-“ Polarity Display OL Overloading Display Battery Deficiency General Specifications (Scope) 160 x 160 Monochrome Display Auto set the Meter according to the tested signal size Auto setting Display OL...
  • Page 45: Feature Summary

    OS-81B Oscilloscope multimeter Feature Summary 160 x 160 Monochrome Display When it is under multimeter mode, the Meter automatically selects Autorange best range Beeper sounds for resistance readings below threshold. Continuity Measure signal on or off time in %. Duty Cycle Battery replaceable.
  • Page 46: Basic Specifications (Scope)

    Basic Specifications (Scope) Horizontal Vertical Sampling rate 40M per second Bandwidth 8MHz Sampling rate / Scale 20 pixels Channel Single Updating rate >5 Coupling Trigger types Free Run / Normal / Voltage resolution 8 Bits Single Shot Timebase Range 100ns/div~5 sec /div Input Impedance 10MΩ...
  • Page 47: Dc Voltage

    OS-81B Oscilloscope multimeter A. DC Voltage Range Resolution Accuracy Overload Protection Input Impedance 400mV 100 µ V Around 10MΩ (0.8%+8) 1000V DC or AC 10mV (excluding waveform) 400V 100mV (0.1%+8) 1000V B. AC Voltage Range Resolution Accuracy Overload Protection Input Impedance 10mV Around 10MΩ...
  • Page 48: Dc Current

    C. DC Current Range Resolution Accuracy Overload Protection 400 µ A 0.1 µ A (1%+8) F0.5AH/250V, ø5×20mm 4000 µ A 1 µ A 40mA 10 µ A (1.2%+8) 400mA 100 µ A F10AH/250V, ø5×20mm. (1.5%+8) (Continuous measurement 10 seconds 10mA and interval more than 15 minutes.)
  • Page 49: Ac Current

    OS-81B Oscilloscope multimeter D. AC Current Range Resolution Accuracy Overload Protection 400 µ A 0.1 µ A (1.5%+8) 4000 µ A 1 µ A F0.5AH/250V, ø5×20mm 40mA 10 µ A (2%+8) 400mA 100 µ A F10AH/250V, ø5×20mm (2.5%+5) 10mA (Continuous measurement 10 seconds...
  • Page 50: Resistance

    E. Resistance Range Resolution Accuracy Overload Protection 400Ω 0.1Ω (1.2%+5) 4kΩ 1Ω 40kΩ 10Ω (1%+5) 250VDC or AC rms 400kΩ 100Ω 4MΩ 1kΩ (1.2%+5) 40MΩ 10kΩ (1.5%+5) F. Diode Test Range Resolution Overload Protection Remarks A good silicon junction drops 250V DC or AC between 0.5V and 0.8V.
  • Page 51: Continuity Test

    OS-81B Oscilloscope multimeter G. Continuity Test Test Range Resolution Overload Protection Remarks  The buzzer sounds when the test resistance is 10Ω. 0.1 Ω 250V DC or AC  The buzzer does not sound when the test resistance is 100Ω.
  • Page 52 I. Capacitance Range Resolution Accuracy Overload Protection 40nF 10pF Under REL mode: (3%+10) 400nF 100pF 250V DC or AC rms 4 µ F (3%+8) 40 µ F 10nF 100 µ F 100nF (4%+8)
  • Page 53 OS-81B Oscilloscope multimeter ** END ** This operating manual is subject to change without notice.
  • Page 54 TECPEL Co., Ltd. TEL : 886-2-27375866 FAX : 886-2-27373343 WWW.TECPEL.COM WWW.OKA.COM.TW...