Alternate Trigger - TECPEL OS Series User Manual

Handheld digital storage oscilloscope & multimeter
Table of Contents

Advertisement

OS Series Handheld DSO & DMM

8.5.3 Alternate trigger

During alternate trigger, the trigger signal mainly comes from two vertical channels and it can be
used to observe two irrelevant signals. You can set different trigger type for two vertical channels
in this menu (optional for edge trigger and video trigger).
Now, you can see a screen that looks like the figure 44.
The Alternate triggering menu is described in the following table.
When the type is set as Edge trigger,
Function menu
CH SEL
Type
Edge type
-->
1/2
Coupling
Figure 44 Alternate Trigger
Settings
Description
CH1
Setting trigger type and others info for Channel 1
CH2
Setting trigger type and others info for Channel 2
Edge
Set vertical channel trigger as edge trigger
Video
Set vertical channel trigger as video trigger
Rising
Triggering on the rise edge of the signal.
Falling
Triggering on the fall edge of the signal.
To next menu
AC
With this mode selected, the DC component is prevented
from passing-though.
DC
All components are allowed.
HF Rjc
The HF part of the signal is prohibited and only the LF
component is allowed.
LF Rjc
The LF part of the signal is prohibited and only the HF
component is allowed.
47