AEMC K100 User Manual

AEMC K100 User Manual

Dc/ac microprobe
Hide thumbs Also See for K100:

Advertisement

Quick Links

DC/AC MICROPROBE
n
ON
AEMC
I N S T R U M E N T S
Shop for AEMC products online at:
E N G L I S H
!
OL
• 1 mV/mA
• OFF
DC/AC MicroProbe
®
Model K100
ShopAEMC
www.
User Manual
K100
K110
.com
1.877.766.5412

Advertisement

Table of Contents
loading

Summary of Contents for AEMC K100

  • Page 1 • 1 mV/mA • OFF AEMC DC/AC MicroProbe ® Model K100 I N S T R U M E N T S ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: E N G L I S H User Manual...
  • Page 2 Model #: K100 / K110 Please fill in the appropriate date as indicated: Date Received: _________________________________ _______________________ Date Calibration Due: Chauvin Arnoux , Inc. ® d.b.a AEMC Instruments ® www.aemc.com ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 3: Table Of Contents

    DC Current Measurement Example - Current Reversed ..12 Two-Wire Sum-of-Currents Example (K100) ......13 Two-Wire Current Differential Example (K100) ......13 Oscilloscope Measurement Example (K100) ......14 Maximum Step Discontinuity Example (K100) ......14 4.4 Model K110 Operation Examples ...........15 Measuring the DC Component of an (AC+DC) Waveform ..15 Measuring the AC Component of an (AC+DC) Waveform ..15 Oscilloscope Measurement Example (K110) ......16 ShopAEMC www. .com 1.877.766.5412 4.5 Tips For Making Precise Measurements ........16 Shop for AEMC products online at: 4.6 Residual Readings Following Severe Overloads ....19...
  • Page 4 5. MAINTENANCE ................20 5.1 Warning ..................20 5.2 Battery Installation ..............20 5.3 Cleaning ..................21 Repair and Calibration ................22 Technical and Sales Assistance ............22 Limited Warranty ...................23 Warranty Repairs ...................23 ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 5: Introduction

    • ALWAYS connect the Model K100/K110 adapter to the display device before clamping the probe onto the sample under test. • ALWAYS inspect the instrument, probe, probe cable and output terminals prior to use. Replace any defective parts immediately. • NEVER use the Model K100/K110 on electrical conductors rated above 300V CAT II, EN61010-1. International Electrical Symbols This symbol signifies that the instrument is protected by double or reinforced insulation. Use only specified replacement parts when servicing the instrument. This symbol on the instrument indicates a WARNING and that the operator must refer to the user manual for instructions before operating the instrument. In this manual, the symbol preceding...
  • Page 6: Definition Of Measurement Categories

    Ordering Information DC/AC MicroProbe Model K100 .......... Cat. #1200.67 DC/AC MicroProbe Model K110 .......... Cat. #2111.73 Both models include an electronic plug-in module with an attached current probe, 9V battery, and user manual Order Accessories and Replacement Parts Directly Online Check our Storefront at www.aemc.com/store for availability...
  • Page 7: Product Features

    Model K110 outputs 10mV per mA of measured current. To take advantage of the Model K100 high sensitivity, best results are obtained through 4-1/2 digit (or more) DMM with a relative zero func- tion. The Model K110 was designed to provide the operator with enhanced low current linearity and accuracy, but is limited to 450mA Peak current. The Model K100/K110 always outputs a signal proportional to the total current (AC+DC) in the conductor under test. This has proven to be the most versatile signal output format, and allows the user to isolate and measure DC and AC components of measured current separately, if so desired. Typical applications include 4 to 20mA loop measurements, auto-...
  • Page 8: Model K100 Features

    Model K100 Features Figure 1 1. Positive: Red banana plug (+) 2. Negative: Black banana plug (-) 3. Power ON indicator (green LED) 4. OVERLOAD indicator (red LED) 5. Power switch 6. Zero adjust knob (push in and turn to zero) 7. Probe window aperture ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: 8. Probe handle DC/AC MicroProbe Models K100 and K110...
  • Page 9: Model K110 Features

    Model K110 Features ® Figure 2 1. Positive: Red banana plug (+) 2. Negative: Black banana plug (-) 3. Power ON indicator (green LED) 4. OVERLOAD indicator (red LED) 5. Power switch 6. Zero adjust knob (push in and turn to zero) 7. Probe window aperture ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: 8. Probe handle DC/AC MicroProbe Models K100 and K110...
  • Page 10: Specifications

    (Reference Conditions: 23°C ± 3°, 20 to 75% RH; battery voltage 9V ± 0.1V; earth’s magnetic www. .com 1.877.766.5412 Shop for AEMC products online at: field < 40 A/m; absence of AC fields; input impedance of display device ≥ 1MΩ/100 pF; DC or sinusoidal AC current 45 to 65Hz.) DC/AC MicroProbe Models K100 and K110...
  • Page 11: Environmental Specifications

    EN61010-1, 300V CAT II CE mark for Electromagnetic Compatibility. Immunity (EN 50082.1), IEC 1000-4-3 aptitude criteria A: DC: 15mV @ 0, AC (60Hz): 2dB from 10mA to 4.5A Emmissivity (EN 50081.1): negligible Drop Test: 1m per IEC 1010 Shocks: 100G per IEC 68-2-27 Vibrations: IEC 529 Protection Index: IP 40 per IEC 529 Electromagnetic Compatibility: EN 50082-1 class A EN 50081-1 *All specifications are subject to change without notice. ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: DC/AC MicroProbe Models K100 and K110...
  • Page 12: Typical Frequency Response

    -3.0 -3.5 -4.0 Figure 3 Model K110 Frequency (Hz) -0.5 -1.0 -1.5 0 - 300 mA RMS -2.0 -2.5 -3.0 -3.5 -4.0 Figure 4 ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: DC/AC MicroProbe Models K100 and K110...
  • Page 13: Operation

    • The Red LED indicates a momentary or continuous overload of the instrument. Readings taken while the Red LED is ON or FLASHING should be considered inaccurate. Momentary or continuous currents exceeding ± 4.7A for Model K100 and 470mA for Model K110, and dynamic currents with large step discontinuities will cause the red LED ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: to turn ON.
  • Page 14: Model K100 Operation Examples

    DC Current Measurement Example - Current Reversed (K100) • Conductor carrying 20.0mA in opposite direction of arrow • Voltmeter placed in DC Volts mode • Voltmeter displays -20.0mV -20.0 20 mA DC PUSH DC Zero Figure 6 ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: DC/AC MicroProbe Models K100 and K110...
  • Page 15: Two-Wire Sum-Of-Currents Example (K100)

    Figure 7 Two-Wire Current Differential Example (K100) • Two conductors in probe aperture (note orientations) • Voltmeter placed in DC Volts mode • Voltmeter displays -4.0mV -4.0 7 mA DC 11 mA DC PUSH DC Zero Figure 8 ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: DC/AC MicroProbe Models K100 and K110...
  • Page 16: Oscilloscope Measurement Example (K100)

    • 1 mV/mA • OFF ® AEMC DC/AC MicroProbe Model K100 I N S T R U M E N T S ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: Figure 10 DC/AC MicroProbe Models K100 and K110...
  • Page 17: Model K110 Operation Examples

    Measuring the AC Component of an (AC+DC) Waveform (K110) • Conductor carrying 20.0mA + 15.0mA • Voltmeter placed in AC Volts mode • Voltmeter displays 150.0mV 150.0 15 mA AC 20 mA DC PUSH DC Zero Figure 12 ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: DC/AC MicroProbe Models K100 and K110...
  • Page 18: Oscilloscope Measurement Example (K110)

    Tips For Making Precise Measurements The Model K100/K110 is capable of making measurements of DC and low frequency currents over a wide range. Here are some key considerations for getting the most accuracy from your displaying instrument: • When using the Model K100/K110 with a meter, it is important to select the range that provides the best resolution. Failure to do this may result in measurement errors. The examples shown on the next page use an ordinary 3-1/2 digit DMM with the Models K100 and K110, to measure 16.7mA ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: DC/AC MicroProbe Models K100 and K110...
  • Page 19 Resolution: 100µV Resolution: 10mV Display Error: 1.8% Display Error: 0% Display Error: 0% PUSH PUSH PUSH DC Zero DC Zero DC Zero 16.7mA ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: Figure 15 DC/AC MicroProbe Models K100 and K110...
  • Page 20: Shopaemc .Com 1.877.766.5412

    • Always zero the Model K100/K110 prior to making a measure- ment. See §4.1 for procedure. • Make sure that probe jaw mating surfaces are free of dust and contamination. Contaminants cause air gaps between sensor halves, making the Model K100/K110 susceptible to external magnetic fields which can contribute to measurement errors. See...
  • Page 21: Residual Readings Following Severe Overloads

    Large short-circuit and transient currents outside the operating range of the Model K100/K110 may cause large residual readings. In extreme cases, the Model K100/K110 will not zero. If this happens: • Remove the probe from the test conductor. • Open the probe and release, allowing the jaws to snap back. Repeat this step several times. • Rezero the instrument before making successive measurements. ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: DC/AC MicroProbe Models K100 and K110...
  • Page 22: Maintenance

    • To avoid electrical shock and/or damage to the instrument, do not get water or other foreign agents into the case. Turn the Model K100/K110 OFF and disconnect the unit from all circuits before opening the case. Battery Installation Your Model K100/K110 has been shipped with a new 9V battery installed. To replace the battery: • Remove probe from any conductor and place it away from any active conductors, circuitry, etc. • Unplug electronic module from display device (e.g. DMM, oscilloscope). • Remove the screws from the bottom cover of the electronic module. • Replace battery with a new 9V alkaline type. • Replace bottom cover and re-attach with screws. BATTERY CLIP SCREWS ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: Figure 16 DC/AC MicroProbe Models K100 and K110...
  • Page 23: Cleaning

    To ensure optimum performance, it is important to keep the probe jaw mating surfaces clean at all times. Failure to do so may result in increased earth’s field susceptibility and overall errors in readings. The following is the recommended procedure for cleaning the probe sensor: (1) Apply a few drops of isopropyl alcohol to an ordinary sheet of white photocopy paper. (2) Open probe to expose the mating surfaces of the sensor and insert the sheet of paper into the jaws. Allow the jaws to close. (3) With the jaws closed, pull free the end of the paper through the jaws until it releases. (4) Repeat step (3) several times, using a new (dry) section of paper each time. (5) Open probe and inspect mating surfaces. They should be free of dust particles or any other contamination. Otherwise, repeat the cleaning process starting again at step (1). ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: Figure 17 DC/AC MicroProbe Models K100 and K110...
  • Page 24: Repair And Calibration

    Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® 200 Foxborough Boulevard Foxborough, MA 02035 USA Phone: (800) 343-1391 (508) 698-2115 Fax: (508) 698-2118 E-mail: techsupport@aemc.com www.aemc.com NOTE: Do not ship Instruments to our Foxborough, MA address. ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at: DC/AC MicroProbe Models K100 and K110...
  • Page 25: Limited Warranty

    Instruments, not by the distributor from ® whom it was purchased. This warranty is void if the unit has been tampered with, abused or if the defect is related to service not performed by AEMC ® Instruments. For full and detailed warranty coverage, please read the Warranty Coverage Information, which is attached to the Warranty Registration Card (if enclosed) or is available at www.aemc.com.
  • Page 26 Notes: ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 27 ShopAEMC www. .com 1.877.766.5412 Shop for AEMC products online at:...
  • Page 28 07/10 99-MAN 100091 v11 ShopAEMC www. .com 1.877.766.5412 Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® Shop for AEMC products online at: 15 Faraday Drive • Dover, NH 03820 USA • Phone: (603) 749-6434 • Fax: (603) 742-2346 www.aemc.com...

This manual is also suitable for:

K110

Table of Contents