I N S T A L L A T I O N G U I D E L I N E S
HIBERNATION MODE
This mode disables motors and most electronics in order to reduce wear on the fixture's internal
components. The user has the ability the define the period of time that the fixture can remain inactive
before it enters hibernation mode. This feature can be accessed by navigating in the main menu to
PERSONALITY > STATUS SETTINGS > HIBERNATION (see the System Menu section of this manual
for detailed information). The default setting for hibernation delay time is 15 minutes, but it can be
adjusted from 1 min to 99 min, or switched off completely.
Hibernation mode is activated under the following conditions:
• Loss of DMX signal: the fixture enters hibernation after the timeout expires. Default is 15 minutes.
• Remote DMX control: Press and hold "Hibernate Fixture" for 3s.
Hibernation mode is deactivated under the following conditions:
• DMX signal is connected.
• Remote DMX control: Hold "Hibernate Off" for 3s.
The fixture will perform a full calibration cycle, then assume the current DMX status.
Please note that the Hibernation does not change the PT position of the fixtures. This allows the user
to set the desired position and then issue the Hibernate command.