T O R Q U E S E T T I N G S F O R S C R E W S
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES!
TO CONFIRM THE IP65 INTEGRITY AFTER A GOBO REPLACEMENT, TEST FIXTURE
USING THE ELATION IP TESTER. CONTACT ELATION SERVICE FOR MORE
DETAILS.
CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS STRONGLY
RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST! AVOID PLACING
YOUR FACE, EYES, HANDS, ETC IN CLOSE PROXIMITY TO THE FIXTURE'S LENS
WHILE
Test Type
Vacuum Test
Pressure Test
IP PRESSURE TESTING PARAMETERS
Low Pressure Limit
-4.35 psi
(-30.00 KPa)
3.62 psi
(25.00 KPa)
High Pressure Limit
-5.08 psi
(-35.00 KPa)
4.35 psi
(30.00 KPa)
21
Hold Time
10 sec
10 sec