Champion 100515 Installation Manual

Champion 100515 Installation Manual

Home standby generator
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION MANUAL
HOME STANDBY GENERATOR
Model 100515 (14 kW)
Model 100304 (22 kW)
REGISTER YOUR PRODUCT ONLINE
at championpowerequipment.com
or visit championpowerequipment.com
SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do
so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
No part of this publication may be reproduced or used in any form by any means – graphic, electronic or mechanical, including photocopying, recording, taping or
information storage and retrieval systems – without the written permission of Champion Power Equipment (CPE).
REV 20230825
Champion Power Equipment, Inc., Santa Fe Springs, CA USA

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 100515 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Champion 100515

  • Page 1 No part of this publication may be reproduced or used in any form by any means – graphic, electronic or mechanical, including photocopying, recording, taping or information storage and retrieval systems – without the written permission of Champion Power Equipment (CPE).
  • Page 2 Have questions or need assistance? Do not return this product to the store! WE ARE HERE TO HELP! Visit our website: www.championpowerequipment.com for more info: Product Info & Updates Tech Bulletins Frequently Asked Questions Product Registration – or – Call our Customer Care Team Toll-Free at: 1-877-338-0999 * We are always working to improve our products.
  • Page 3: Table Of Contents

    14-kW (Model 100515) Specifications ......22-kW (Model 100304) Specifications ......14-kW (Model 100515) Engine Torque Specifications ..22-kW (Model 100304) Engine Torque Specifications ..
  • Page 4: Introduction

    ® INTRODUCTION HOME STANDBY GENERATOR Congratulations on your purchase of a Champion Power Equipment This home standby generator is intended exclusively for outdoor installation. This generator will operate using either liquified (CPE) product. CPE designs, builds, and supports all of our products to strict specifications and guidelines.
  • Page 5: Safety

    SAfETY HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® SAfETY Safety Definitions The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, deserve your careful attention and understanding. The safety warnings do not by themselves eliminate any danger. The instructions or warnings they give are not substitutes for proper accident prevention measures.
  • Page 6: Safety Symbols

    SAfETY HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product. SYMBOL MEANING Read Operator’s Manual.
  • Page 7 SAfETY HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® SYMBOL MEANING Sever hazard (rotating blade) Crush hazard (top)
  • Page 8: Important Safety Instructions

    IMPORTANT SAfETY INSTRUCTIONS HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® IMPORTANT SAfETY INSTRUCTIONS DANGER  Carbon Monoxide (CO) is a colorless, odorless, poisonous WARNING  gas. Breathing carbon monoxide will cause nausea, dizziness, Cancer and Reproductive Harm – www.P65Warnings.ca.gov fainting or death.
  • Page 9: Installation Hazards

    POSITIVE, POS or (+) battery cable. generator. To return the generator to service, follow these steps in order: For service or parts assistance, contact your Champion dealer 1. Connect the POSITIVE, POS or (+) battery cable first, and if repairs are needed.
  • Page 10: Electrical Shock Hazards

    IMPORTANT SAfETY INSTRUCTIONS HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® Electrical Shock Hazards Burn Hazards WARNING WARNING   Use extreme caution when near the generator while it is DO NOT touch hot surfaces. operating. The generator produces dangerous voltage. ALWAYS avoid contact with hot exhaust components and Avoid contact with bare wires, terminals and connections while gases.
  • Page 11: Safety Labels And Hang Tags

    C- updated font size per GP. This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
  • Page 12 B: updated some text per DL. on white substrate. This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
  • Page 13: Safety, Serial/Model, Nameplate Label Locations

    If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement. A. Serial number location D. Oil hang tag B. Nameplate E. Alternate power source (not shown – in the Operators Manual bag) C. NFPA 37 Compliance F. Flexible Fuel Line hang tag 14-kW (Model 100515) 22-kW (Model 100304)
  • Page 14: Specifications

    SPECIfICATIONS HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® SPECIfICATIONS 14-kW (Model 100515) Specifications Home Standby Generator Maximum continuous power, LPG 14 kW Maximum continuous power, NG 12.5 kW Rated voltage 120/240 Amps 116.6/58.3 LPG (propane), 104/52 NG (natural gas)
  • Page 15: 22-Kw (Model 100304) Specifications

    SPECIfICATIONS HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® 22-kW (Model 100304) Specifications Home Standby Generator Maximum continuous power, LPG 22 kW Maximum continuous power, NG 19.8 kW Rated voltage 120/240 Amps 183.4/91.7 LPG (propane), 165/82.5 NG (natural gas) Harmonic distortion Less than 5% Main line circuit breaker 100 amp...
  • Page 16: 14-Kw (Model 100515) Engine Torque Specifications

    SPECIfICATIONS HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® 14-kW (Model 100515) Engine Torque Specifications Crankcase Cover Bolts ......27 Nm (20 lbf-ft) Connecting Rod Bolts ......
  • Page 17: Alternator Overview

    UNPACkING HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® UNPACkING Alternator Overview The alternator is made up with the following major components; WARNING  1. Brush holder assembly The HSB weighs more than 500 lbs. (227 kg). 2. Rear bearing carrier Use the aid of additional assistants and exercise caution during 3.
  • Page 18: Installation

    INSTALLATION HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® INSTALLATION Placement & Installation Guidelines for Champion Home Standby Generators to Reduce the Risk of fire NATIONAL fIRE PROTECTION ASSOCIATION (NfPA) Annex A Explanatory Material STANDARD NfPA 37 REQUIREMENTS AND TESTING A.4.1.2 (2) Means of demonstrating compliance are by means of...
  • Page 19: Intertek Group Plc Label

    All walls of the structure that are closer than 5 ft. from the engine enclosure have a fire resistance rating of at least 1 hr., or This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
  • Page 20: Site Selection, Preparation And Placement

    INSTALLATION HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® Champion HSB units have been run and tested at the factory prior DANGER  to shipment. They do not require any type of break-in period. Engine exhaust from the unit is hot, poisonous and dangerous.
  • Page 21 HSB from the wood pallet, dragging it off the wood pallet will damage the HSB base. The HSB must be lifted If no concrete pad is being used, Champion recommends using a from the wood pallet to separate.
  • Page 22: Installation Preparation

    14-kW (Model 100515) on the front panel and turn the circuit breaker to the OFF position. Champion HSB units have been run and tested at the factory prior to being shipped. They do not require any type of break-in period.
  • Page 23 1. fUEL REQUIREMENTS AND RECOMMENDATIONS Fuel System Requirements The following NG and LPG fuel information is provided to assist 14-kW (Model 100515) the fuel installer. This information should not be deemed to be Fuel System all inclusive or to conflict with local dry fuel codes. Consult your...
  • Page 24 INSTALLATION HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® diameter is extended in length, its ability to carry the volume of 14-kW (Model 100515) gas is diminished in direct proportion. Percent Fuel Type Consumption BTU/Hr Pipe sizes are measured by inside diameter (ID) to include any of load fittings, valves, elbows, tees or angles.
  • Page 25 Refer to the “Fuel Pipe Sizing Chart” contained in this manual. Btu’s for the HSB and all connected appliances. Champion HSB units have been run and tested at the factory prior to shipment. They do not require any type of break-in period.
  • Page 26 5. CONVERTING TO LPG 4. Install LPG jets and gasket (6) to fuel inlet chamber. Jet Change Procedures - 14-kW (Model 100515) Left side main jet: Size #410 (11) The engine is fitted with a dual Master Mixer Assembly (carburetor Right side main jet: #430 (12) system), which allows the HSB to run on either NG or LPG.
  • Page 27 INSTALLATION HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® Mixer Change procedures - 22-kW (Model 100304) 4. Connect breather tube (1) to breather port and put clamp (2) on breather tube. The engine is fitted with a dual Master Mixer Assembly (carburetor system), which allows the HSB to run on either NG or LPG.
  • Page 28 Recheck you initial calculations to manual. ensure where the problem might exist. Champion HSB units have been run and tested at the factory. They do not require any type of 14-kW (Model 100515) break-in period.
  • Page 29 INSTALLATION HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® to ground to starter Recommended Battery Type To starter To ground 350 CCA min 300 CCA min °F 104+ °C Ambient temperature Battery Series Cable U1L Battery Post Style 4. Dielectric grease should be applied on the battery connections to aid in the prevention of corrosion.
  • Page 30 INSTALLATION HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® 1. Place the batteries under the cover behind the aXis controller. 7. Inspect, clean or re-grease battery connections every two Remove four M6 x 12 bolts using a 10mm wrench (not months.
  • Page 31: Battery Charger

    2mm safe margin; to be printed on White substrate. This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
  • Page 32 INSTALLATION HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® Wire Land SYMBOL DESCRIPTION Function Wire Color Points DC Voltage Adjustment - Preset Wire land #1 Ground G (green) from the factory for proper DC charger output. No adjustments Wire land #2 P (pink) necessary.
  • Page 33 INSTALLATION HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® CAUTION  The electrolyte is a diluted sulfuric acid that is harmful to the skin and eyes. It is electrically conductive and corrosive. The following procedures are to be observed: 1. Wear full eye protection and protective clothing, 2.
  • Page 34: Surge Protection

    Make sure conductor wires are labeled and/or marked accordingly. AVR = Automatic Voltage Regulator 14-kW (Model 100515) The AVR is an electrical or electronic device that maintains the voltage of a power source within predetermined limits. AVR is a...
  • Page 35: Engine Relay Module

    There are 12 wire land points in the top row, the connection points are all the same size. Engine Relay Module 14-kW (MODEL 100515) This module is the interface between the Engine Controller, ATS Controller, alternator, hour meter and battery charger. It is the interface for all on board communications in the HSB.
  • Page 36: Exterior Warning Led

    INSTALLATION HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® Wire Land 14-kW (Model 100515) Function Wire Color Points Position #4 Not connected Empty Position #5 High engine temperature BR (brown) Position #6 Low oil level/pressure Y (yellow) Position #7 Not connected...
  • Page 37: Microswitch

    INSTALLATION HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® 22-kW (MODEL 100304) To access this microswitch, remove four M6 x 12 bolts from the cover using a 10mm wrench (not included). This generator has ON/OFF switches that when turned off, will shut down the HSB (if running) and deactivate the aXis controller preventing future starts.
  • Page 38 Check the oil level. The oil level should be at the FULL mark, if necessary, add oil. DO NOT overfill. Inspect the unit for a possible oil leak, if a leak is discovered, contact Champion or your nearest Authorized Champion Dealer. Follow the FAULT CODE RESET...
  • Page 39 30 minutes, follow the FAULT CODE RESET instructions to clear the fault after service. Champion Dealer. The RED icon will remain lit until the failure has been corrected, the HSB will not attempt to transfer or run. 5. Close the enclosure doors and the unit is ready to run.
  • Page 40: Wi-Fi Setup Method

    Follow the FAULT CODE RESET in near proximity to the ATS. instructions to clear the fault after service. 2. Search and connect to network name (SSID) “Champion Requires Maintenance ####” where #### will match the last four digits of the serial number that is printed on the control board.
  • Page 41 Choose Hour... 3. After connecting Wi-Fi, open your device’s web browser. In the browser address change the address to 192.168.0.90 and Choose Minute... begin search. This will direct your browser to the Champion aXis Controller Home Standby Generator Settings page ®...
  • Page 42 Home Standby Generator Settings INSTALLATION HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® Generator Date and Time 6. Some operating systems will require additional steps to 8. Confirm and apply the settings before continuing. Unsaved confirm update, accept all pop-up windows until progress bar changes are highlighted.
  • Page 43: Ats And Hsb Status Using Wifi

    3. Year (Y) - choose current year (example 2021 would be 21) with 18 to 47. 1. Using a WIFI enabled device, connect to the “Champion HSB” Set year using WIFI network following steps 1, 2, and 3 from WIFI Setup MODE Method.
  • Page 44 INSTALLATION HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® Week Day (exercise) - choose week day from 1 to 7. The pins relate to a function of the aXis Controller. These functions control the operation of the HSB aXis Controller module.
  • Page 45: Automatic Transfer Switch (Ats)

    HSB troubleshooting, and warranty. functioning (see NEC 700, 701 and 702). Failure to disconnect the After Performing Installation of Champion ATS with aXis home from the utility with an approved UL listed ATS can result Controller , complete the following steps to finish the installation ®...
  • Page 46: Hsb Test

     HSB Test Proceed with caution. Once the Utility Power is turned ON, the SPEED SETTING NO LOAD - 14-kW (MODEL 100515) ATS is now electrically hot. The feeder lines and terminals are now live. Do NOT move forward until the HSB generator AC output voltage and frequency are correct and within the stated limits.
  • Page 47 INSTALLATION HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® 10. Measure across GENERATOR SUPPLY ATS lugs L1 and L2. Also check L1 to NEUTRAL. These are factory, no load, pre- set limits. Frequency ..............62.5 Hertz Terminals L1 to L2 ............240 VAC Terminals L1 to NEUTRAL ..........120 VAC Terminals L2 to NEUTRAL..........120 VAC 3.
  • Page 48: Checking Automatic Operation

    INSTALLATION HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® 5. The aXis Controller screen will indicate that the generator is If the aXis Controller HSB is being connected to a ® now suppling power to the home. non-aXis Controller ATS, it will be necessary to use a two-wire ®...
  • Page 49: Maintenance

    MAINTENANCE HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® Full flow shutoff valve Automatic operation of the HSB system Battery Charger and LED indicators Exterior warning LED on the backside of the HSB ATS operation Exercise scheduled time of operation Scheduled Maintenance Fill out and provide the customer a copy of the HSB, ATS model &...
  • Page 50 MAINTENANCE HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® 102006, 102007, 102008, 102009, 102010 ATS Wiring Diagram...
  • Page 51: Troubleshooting Hsb

    Check either single or dual generator ON/OFF switches are in the ON Generator ON/OFF switch is in the OFF position. position (inside on 100515 and 100304, on the back for 100304). Generator will crank/turn over but will not start Check for active fault code.
  • Page 52 BATTERY(S) NO OR LOW LEVEL CHARGED, BATTERY(S) DEAD, NEEDS REPLACEMENT, THE EXERCISE TIME MUST BE RESET ONCE THE BATTERY(S) HAVE BEEN DISCONNECTED. * *Contact Champion Power Equipment, Technical Service toll free 1-877-338-0999, tech@championpowerequipment.com or your nearest Champion dealer. www.championpowerequipment.com...
  • Page 53: Hsb, Ats Model & Serial Reference Ats Back-Up Circuits

    TROUBLESHOOTING HSB HOME STANDBY GENERATOR- ALL aXis CONTROLLER MODELS ® HSB, ATS Model & Serial Reference ATS Back-up Circuits HSB Model Number HSB Serial Number Fuel Type ATS Model Number ATS Serial Number ATS circuits powered Date Installed Dealer/Installer Address Phone Cell Purchased from...
  • Page 54 Ninguna parte de esta publicación puede ser reproducida o utilizada en forma alguna por ningún medio — gráfico, electrónico o mecánico, incluyendo fotocopias, grabaciones, cintas o sistemas de almacenamiento y recuperación de información — sin el permiso escrito de Champion Power Equipment (CPE).
  • Page 55 - o - Llame a nuestro equipo de atención al cliente al teléfono gratuito: 1-877-338-0999 Este manual debe ser usado con los manuales de Champion Power Equipment (CPE): Manual de instalación, Parte N.° 101951 Manual del interruptor de transferencia, Parte N.° 101948...
  • Page 56 Instalación ............... Guías de colocación e instalación de los generadores de energía Introducción ..............de reserva para uso doméstico de Champion para reducir el riesgo de incendio ..............Generador de energía de reserva para uso doméstico Etiqueta de Intertek Group PLC ..........
  • Page 57: Introducción

    INTRODUCCIÓN GENERADOR DE ENERGÍA DE RESERVA PARA USO DOMÉSTICO Felicitaciones por la compra de este producto de Champion Power Equipment (CPE). CPE diseña, fabrica y brinda asistencia técnica Este generador de energía de reserva para uso doméstico está para todos nuestros productos según estrictas especificaciones destinado exclusivamente a la instalación en exteriores.
  • Page 58: Seguridad

    SEGURIDAD GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® SEGURIDAD Definiciones de seguridad El propósito de los símbolos de seguridad es llamar su atención sobre los posibles peligros. Los símbolos de seguridad, y sus explicaciones, merecen su cuidadosa atención y comprensión. Las advertencias de seguridad no eliminan por sí...
  • Page 59: Símbolos De Seguridad

    SEGURIDAD GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® Símbolos de seguridad Algunos de los siguientes símbolos pueden utilizarse en este producto. Estúdielos y aprenda su significado. La correcta interpretación de estos símbolos le permitirá utilizar el producto con mayor seguridad. SÍMBOLO SIGNIFICADO Lea el manual del operador.
  • Page 60 SEGURIDAD GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® SÍMBOLO SIGNIFICADO Peligro de amputación (aspa giratoria) Peligro de aplastamiento (arriba)
  • Page 61: Instrucciones De Seguridad Importantes

    INSTRUCCIONES DE SEGURIDAD IMPORTANTES GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® INSTRUCCIONES DE SEGURIDAD Peligros de la instalación IMPORTANTES ADVERTENCIA  ADVERTENCIA Asegúrese de que solo un electricista o técnico de instalación  calificado que esté familiarizado con los códigos, normas Cáncer y daños en el sistema reproductivo: y regulaciones aplicables instale y realice el mantenimiento www.P65Warnings.ca.gov...
  • Page 62: Peligros En El Funcionamiento

    INSTRUCCIONES DE SEGURIDAD IMPORTANTES GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® Peligros en el funcionamiento Peligros del monóxido de carbono ADVERTENCIA PELIGRO   Opere SIEMPRE el generador siguiendo las instrucciones del – El generador debe ser instalado y operado solo en fabricante.
  • Page 63: Peligros De Descarga Eléctrica

    INSTRUCCIONES DE SEGURIDAD IMPORTANTES GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® Peligros de descarga eléctrica Peligros de incendio/explosión ADVERTENCIA ADVERTENCIA   Tenga mucho cuidado al estar cerca del generador durante su El gas natural (NG) y el gas licuado de petróleo (LPG) son funcionamiento.
  • Page 64: Peligros De Enredos

    INSTRUCCIONES DE SEGURIDAD IMPORTANTES GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® Peligros de enredos ADVERTENCIA  Tenga mucho cuidado cuando esté cerca de las piezas giratorias. En las piezas giratorias pueden enredarse las manos, los pies, el cabello, la ropa y/o los accesorios. Se puede producir una amputación traumática o una laceración grave.
  • Page 65: Etiquetas De Seguridad Y Etiquetas Colgantes

    3mm corner radius; 2mm safe margin; to be printed on white substrate. This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
  • Page 66 3mm corner radius; 2mm safe margin; to be printed on white substrate. This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
  • Page 67: Seguridad, Serie/Modelo, Ubicación De Las Etiquetas De Las Placas De Identificación

    ETIqUETAS DE SEGURIDAD y ETIqUETAS COLGANTES GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® Seguridad, Serie/Modelo, Ubicación de las etiquetas de las placas de identificación Las etiquetas de seguridad tienen una ubicación específica y deben ser reemplazadas si son ilegibles, están dañadas o faltan. A.
  • Page 68: Especificaciones

    ESPECIfICACIONES GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® ESPECIfICACIONES Especificaciones del HSB de 14 kW Generador de energía de reserva para uso doméstico Máxima potencia continua, LPG 14 kW Máxima potencia continua, NG 12.5 kW Voltaje nominal 120/240 Amperios 116.6/58.3 LPG (propano), 104/52 NG (gas natural)
  • Page 69: Motor Champion 754 Cc

    Motor Champion 754 cc El motor de 754 cc fue desarrollado por Champion Engine Technology para ser usado en los generadores de energía de reserva para uso doméstico de Champion. El diseño bicilíndrico en V proporciona un alto rendimiento, funcionamiento eficiente, bajo mantenimiento y una larga vida útil demostrada.
  • Page 70: Descripción Del Alternador

    DESEMBALAjE GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® DESEMBALAjE Descripción del alternador El alternador está compuesto por los siguientes componentes ADVERTENCIA  principales; 1. Conjunto de portaescobillas El HSB pesa más de 500 libras. (227 kg). Utilice la ayuda de asistentes adicionales y tenga cuidado 2.
  • Page 71: Instalación

    Estas guías se basan en las pruebas contra incendios del recinto combustibles fuera del recinto. del generador y en el requisito de Champion de flujo de aire para su correcto funcionamiento. Los códigos locales pueden ser diferentes y más restrictivos.
  • Page 72: Etiqueta De Intertek Group Plc

    Todas las paredes de la estructura que están más cerca de 5 ft del recinto del motor deben tener una resistencia al fuego de al menos 1 This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for hora, o outside parties without the explicit consent of Champion Power Equipment.
  • Page 73: Selección, Preparación Y Colocación De La Ubicación

    Use las mismas precauciones general de la unidad. El Champion HSB se envía desde la fábrica cuando instale el HSB en la línea de la propiedad, cerca de la casa preparado para el combustible de gas natural (NG).
  • Page 74 Champion (modelo 100616) y el HSB se asegura a ella. En algunas zonas se requiere una plataforma de hormigón debido al el memorando de pérdida o daño del consignador.
  • Page 75: Preparación De La Instalación

    OFF. Las unidades HSB de Champion han sido puestas en marcha y probadas en la fábrica antes de ser enviadas. No requieren ningún tipo de periodo de asentamiento.
  • Page 76 INSTALACIÓN GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® Requisitos del sistema de combustible de 14 kW locales de combustibles secos. Consulte con su proveedor local de combustible o al jefe de bomberos para obtener orientación sobre Requisitos los códigos e instalaciones locales adecuados.
  • Page 77 INSTALACIÓN GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® 3. TAMAÑO DE LA TUBERÍA DE NG LÍNEA DE COMBUSTIBLE fLEXIBLE El HSB sale de la fábrica configurado para NG, no es necesario Se instalará una línea de combustible flexible (incluida en el hacer cambios ni modificaciones si el NG es la fuente de HSB) entre el tubo de suministro de combustible fijo y el tubo combustible que se utilizará.
  • Page 78 HSB. Las unidades HSB de Champion han sido puestas regulador de combustible primario y están destinados a la en marcha y probadas en la fábrica antes de su envío.
  • Page 79 INSTALACIÓN GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® 5. CONVERSIÓN A LPG 4. Instale las boquillas de LPG y la junta (6) en la cámara de entrada de combustible. El motor está equipado con un conjunto de mezclador maestro –...
  • Page 80 Vuelva a revisar sus cálculos iniciales para comprobar Unión de tubos de 4 vías Trampa de sedimentos dónde podría existir el problema. Las unidades HSB de Champion han sido puestas en marcha y probadas en la fábrica. No requieren ningún tipo de periodo de asentamiento.
  • Page 81 INSTALACIÓN GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® 9. REqUISITOS DE LA BATERÍA, INSTALACIÓN y SERVICIO 6. Se debe aplicar grasa dieléctrica en las conexiones TÉCNICO de la batería para ayudar a prevenir la corrosión. El tamaño de las baterías es un tema que se analiza y debate 7.
  • Page 82 INSTALACIÓN GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® 10. CABLEADO DEL HSB ADVERTENCIA  Tamaño del cable No tire la batería o las pilas al fuego. La batería es capaz Todas las instalaciones deben cumplir con los códigos locales, de explotar.
  • Page 83: Protección Contra Picos Repentinos

    INSTALACIÓN GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® o disminuye en consecuencia. El AVR calcula cuánto voltaje debe PRECAUCIÓN  ser enviado al excitador varias veces por segundo, mientras estabiliza el voltaje de salida a un punto de ajuste predeterminado. Use una llave de torsión para apretar los conductores, asegurándose de no apretarlos demasiado, ya que podría Hay 3 conectores que vienen del AVR.
  • Page 84: Módulo De Relé Del Motor

    INSTALACIÓN GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® El potenciómetro ranurado viene configurado de fábrica con el voltaje correcto y no debería requerir ajuste. fILA SUPERIOR Hay 12 puntos de conexión con cables en la fila superior, los puntos de conexión son todos del mismo tamaño.
  • Page 85: Led De Advertencia Exterior

    INSTALACIÓN GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® Puntos de conexión Función Color del cable de los cables Posición N.° 8 Válvula de suministro G/B (verde/negro) de combustible Posición N.° 9 Arranque B/W (blanco/negro) Posición N.° 10 Detención L/B (azul/negro) Posición N.°...
  • Page 86 Inspeccione la unidad por una posible filtración un corte de energía y durante el ciclo de uso semanal. Esto de aceite, si se descubre una filtración, contacte a Champion o proporciona al propietario un registro del tiempo de funcionamiento, al Distribuidor autorizado de Champion más cercano.
  • Page 87 RESTABLECIMIENTO DEL CÓDIGO DE FALLA encenderá. para borrar la falla después del servicio. Si se produce esta falla, comuníquese con Champion o con el 5. Cierre las puertas del recinto y la unidad estará lista distribuidor autorizado de Champion. El ícono ROJO permanecerá...
  • Page 88: Método De Configuración Wifi

    RESTABLECIMIENTO DEL CÓDIGO DE FALLA para inteligente, tableta, etc.) en las proximidades del ATS. borrar la falla después del servicio. 2. Busque y conéctese al nombre de la red (SSID) “Champion Requiere mantenimiento XXXX” donde XXXX igualará los ultimos cuatro digitos del numero de serie que esta impreso en el tablero de control.
  • Page 89 AVISO  USE DEVICE DATE & TIME Durante la configuración, su dispositivo se desconectará del Internet. El Champion Wi-Fi es una conexión directa entre el dispositivo (portátil, teléfono inteligente, tableta, etc.) y el Date: Choose Month... ATS, y no se conecta al Internet. Unos dispositivos Android Wi-fi pueden mostrar la siguiente pantalla - Elija “Connect only this...
  • Page 90 Home Standby INSTALACIÓN GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® Generator Settings 5. Confirme y guarde la configuración antes de continuar. Si no 7. Establezca la frecuencia y el horario de las pruebas de confirma de inmediato, el reloj estará mas tarde de lo actual. operación de HSB.
  • Page 91: Estado Ats Y Hsb Con Wifi

    1. Para comenzar a programar, deshabilite AUTO seleccionando 1. Utilizando un dispositivo habilitado para WIFI, conéctese a la red WIFI “Champion HSB” siguiendo los pasos 1, 2 y 3 del ARRÊT 2. Después de que el HSB esté configurado en OFF, mantenga método de configuración WIFI.
  • Page 92 INSTALACIÓN GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® Minuto (uso) - elija el minuto entre 0-59. — 2= Martes — 3= Miércoles Configurar el minuto usando MODE — 4= Jueves para el próximo — 5= Viernes 12. Cuando haya terminado, presione OFF para guardar todos los —...
  • Page 93: Cargador De Batería

    Este cargador automático de baterías es un módulo inteligente This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for de la batería. Si esta luz LED se enciende, el ícono LED outside parties without the explicit consent of Champion Power Equipment.
  • Page 94: Interruptor De Transferencia Automática (Ats)

    L1 y N a los cables de tierra n.° 2 y n.° 3, respectivamente. y la garantía. Después de realizar la instalación del ATS de Champion con el Interruptor de transferencia automática (ATS) aXis Controller , complete los siguientes pasos para terminar la ®...
  • Page 95: Puesta En Funcionamiento Del Ats

    INSTALACIÓN GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® Puesta en funcionamiento del ATS Prueba del HSB 1. Ponga el controlador del motor del HSB en la posición "OFF" AjUSTE DE VELOCIDAD SIN CARGA (APAGADO). NO avance hasta que el voltaje y la frecuencia de salida de CA 2.
  • Page 96 INSTALACIÓN GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® ADVERTENCIA PELIGRO   El fabricante recomienda que un electricista con licencia o una Proceda con cautela. El voltaje de salida del generador HSB persona con amplios conocimientos de electricidad realicen se suministra al ATS y está...
  • Page 97: Verificación Del Funcionamiento Automático

    INSTALACIÓN GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® PRUEBAS DEL HSB BAjO CARGA 3. Permita que el sistema pase por un ciclo completo. (Aproximadamente 7 minutos) Durante esta prueba NO es necesario apagar ningún disyuntor del Panel de distribución principal del servicio eléctrico, 4.
  • Page 98: Resumen De La Familiarización Del Cliente

    MANTENIMIENTO GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® MANTENIMIENTO Antes de realizar los procedimientos de mantenimiento, revise la sección SEGURIDAD del manual del operador. Asegúrese de que el ATS y los interruptores del motor estén en la DIP1_TIEMPO DE PARADA DE MOTOR posición OFF antes de realizar cualquier mantenimiento o limpieza.
  • Page 99 MANTENIMIENTO GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® 102006, 102007, 102008, 102009, 102010 Diagrama de cableado del ATS...
  • Page 100: Solución De Problemas Del Hsb

    El generador está sobrecargado para la vivienda. Si el problema vuelve a aparecer, comuníquese con Champion o con el distribuidor de servicios de Champion *. Revise la ventilación de entrada y salida alrededor del HSB, retire todos los Temperatura alta/excesiva del motor apagada...
  • Page 101 BATERÍA(S) NO CARGADA(S) O CON BAJO NIVEL DE CARGA, BATERÍA(S) MUERTA(S), NECESITA(N) SER REEMPLAZADA(S), EL TIEMPO DE USO DEBE RESTABLECERSE UNA VEZ QUE LA(S) BATERÍA(S) HA(N) SIDO DESCONECTADA(S). * *Contacte a la línea gratuita del servicio técnico de Champion Power Equipment por el 1-877-338-0999, tech@championpowerequipment.com o al distribuidor Champion más cercano.
  • Page 102: Referencia De Hsb, Modelo Ats Y Número Serie Circuitos De Respaldo Ats

    SOLUCIÓN DE PROBLEMAS DEL HSB GENERADOR DOMÉSTICO DE RESERVA- TODOS LOS MODELOS aXis CONTROLLER ® Referencia de HSB, Modelo ATS y número serie Circuitos de respaldo ATS Número de modelo de HSB Número de serie del HSB Tipo de combustible LPG Número de modelo de ATS Número de serie del ATS Circuitos de ATS alimentados...
  • Page 103 Certificado Champion Residencial distribuidor de servicio – Instalación original o de los costos de arranque más cercano. Esta garantía se aplica sólo a Champion Power Equipment generadores de reserva automática utilizados en – Generadores Champion residenciales que no utilizan repuestos aplicaciones de “espera”...
  • Page 104 Para obtener el servicio de garantía o su llamada Champion Power – Vivos o gastos de viaje de persona (s) que realiza el servicio, Equipment peaje cercano Champion Residencial concesionario de excepto incluido específicamente dentro de los términos de un...

This manual is also suitable for:

100304

Table of Contents

Save PDF