BQ80S V2 Variable-Speed Peristaltic Pump Safety Precautions Danger Use the correct voltage indicated on the rating plate label of the pump to • avoid any damage. Do not make any unauthorized dismantling, changes or modifications to • the pump which could result in malfunctions or even potential accidents.
Page 4
BQ80S V2 Variable-Speed Peristaltic Pump (DE) SICHERHEITSHINWEISE Gefahr Verwenden Sie die richtige Spannung, die auf dem Typenschild der Pumpe • angegeben ist, um Schäden zu vermeiden. Nehmen keine unbefugten Demontagen, Änderungen oder Modifikationen an der • Pumpe vor, die zu Fehlfunktionen oder sogar zu Unfällen führen könnten.
Page 5
BQ80S V2 Variable-Speed Peristaltic Pump (FR) CONSIGNES DE SÉCURITÉ Danger • Utilisez la tension correcte indiquée sur la plaque signalétique de la pompe afin d'éviter tout dommage. Ne procédez pas à des démontages, changements ou modifications non • autorisés de la pompe qui pourraient entraîner des dysfonctionnements, voire des accidents.
Page 6
BQ80S V2 Variable-Speed Peristaltic Pump (ES) INSTRUCCIONES DE SEGURIDAD Peligro bomba Utilice la tensión correcta indicada en la placa de características de la para • evitar daños. No realice ningún desmontaje, cambio o modificación no autorizada en la bomba •...
Page 7
BQ80S V2 Variable-Speed Peristaltic Pump (IT) ISTRUZIONI DI SICUREZZA Pericolo corretta Usare la tensione indicata sull'etichetta della targhetta della pompa per • evitare qualsiasi danno. Non eseguire smontaggi, cambiamenti o modifiche non autorizzati alla pompa che • potrebbero causare malfunzionamenti o addirittura potenziali incidenti.
BQ80S V2 Variable-Speed Peristaltic Pump 1 Description BQ80S V2 variable-speed peristaltic pump provides not only basic functions such as start/stop, reversible direction and adjustable speed, but also the Time Dispense Mode and Anti-Drip function. With the MODBUS RS485 interface, the pump is easy to communicate with external devices, such as PC, HMI or PLC.
BQ80S V2 Variable-Speed Peristaltic Pump Circuit board with conformal coating to achieve dust and moisture • resistance. Anti-electromagnetic interference feature; wide input voltage range for • complex power environment. ABS engineering plastic housing, streamlined design • 3 Components and Connectors...
BQ80S V2 Variable-Speed Peristaltic Pump 4 Display Panel and Operating Keypads LCD DISPLAY DIRECTION START/STOP MENU Key PRIME DOWN Figure 2. Display Panel 4.1 Keypad UP Key. When pressed shortly, the last digit of the value will increase by 1. Hold the key to increase the value quickly.
BQ80S V2 Variable-Speed Peristaltic Pump 4.2 LCD Screen Display 32.5rpm Figure 3. Display screen 4.2.1 A. Control Mode It displays the current control mode. Press the MENU key, the display will show “Run Mode”, press the START/STOP key to enter the setting of the control...
Page 12
BQ80S V2 Variable-Speed Peristaltic Pump Stopped Running Paused Figure 4. Running State 4.2.3 C. Direction State It shows the current drive direction setting. Clockwise Counterclockwise Figure 5. Direction 4.2.4 Wi-Fi Signal Strength When Wi-Fi is disabled in System Advanced Parameter Settings, it shows the state of the key tone, on or off.
BQ80S V2 Variable-Speed Peristaltic Pump DIRECTION key then release to lock the keypad; press and hold the DIRECTION key then release to unlock the keypad. Keypad unlocked Keypad locked Figure 7. Keypad Lock 4.2.6 F. Communication State It shows the current RS485 communication state.
Page 14
BQ80S V2 Variable-Speed Peristaltic Pump 1.Run Mode Menu 1.Run Mode 2.RunTime Unit Menu 2.RunTime Unit 3.Run Time Menu 3.Run Time 1.0 Sec Menu 4.PauseTime Unit 4.PauseTime Unit 5.Pause Time Menu 1.0 Sec 5.Pause Time 6.Cycles Menu 6.Cycles 7.Reverse Angle Menu 7.Reverse Angle...
BQ80S V2 Variable-Speed Peristaltic Pump 1. RunTime Unit: Time unit for the dispense duration of Time Dispense • mode. The unit can be in days, hours, minutes or seconds. 2. Run Time: Dispense time for Time Dispense mode. It is the dispense •...
Page 16
BQ80S V2 Variable-Speed Peristaltic Pump selection, press key to enter the submenu, press key to adjust parameters. To return to the previous menu, press . To return to the main interface, press key. MENU 1.Baud System 9600 1.Baud 2.Stop Bit System 2.Stop Bit...
Page 17
BQ80S V2 Variable-Speed Peristaltic Pump 1. Baud: In the communication mode, set the baud to 4800, 9600, 19200, • 38400 (the default is 9600). 2. Stop Bit: In the communication mode, set the size of the stop bit, which •...
BQ80S V2 Variable-Speed Peristaltic Pump 7 External Control Interface DB15 Mark Note ADC_W Positive of external analogue input Communication interface, B pole of Communication interface, A pole of VCC_W External voltage input terminal CW_W External input signal to control the...
BQ80S V2 Variable-Speed Peristaltic Pump maintained when it is in operation. 8.2 Power Connection The voltage of the power supply should match with what is indicated on the rating plate label of the pump. Please plug the 24V DC power to the connector on the rear of the pump.
BQ80S V2 Variable-Speed Peristaltic Pump 1) Power on the drive. The pump will display the main screen. 2) Use the MENU to change the mode to Internal Control mode (Int shown on the screen). 3) Press the UP or DOWN key to adjust the speed.
Page 21
BQ80S V2 Variable-Speed Peristaltic Pump CW_W ADC_W AGND RS_W VCC_W 0-5V/0-10V /4-20mA 5V/12V/24V DC Figure 14. DB15 Wiring with External Power Source CW_W ADC_W AGND RS_W 0-5V/0-10V /4-20mA Figure 15. DB15 Wiring with the Internal 12VDC Power Source 2) Power on the pump. The pump will display the main screen.
BQ80S V2 Variable-Speed Peristaltic Pump 8.6 Time Dispense Mode The pump will dispense fluid automatically by setting duration for each dose, pause time between doses and the number of cycles. When dispensing, the display will show the dispensing time or lag time that has passed (1.2s in Figure 16), and the total cycles (4 in Figure 16) that has dispensed.
BQ80S V2 Variable-Speed Peristaltic Pump 2) Press the START/STOP key to start dispensing. 3) When the drive is running, press the START/STOP key to stop the drive at any time. 4) A footswitch can be used to start/stop the pump.
BQ80S V2 Variable-Speed Peristaltic Pump RS_W VCC_W 5V/12V/24V DC Figure 20. Logic Level 1 Control with External Power Source 2) Power on the pump.The pump will display the main screen. 3) Use the MENU to change the mode to Logic Level 1 control mode (shows Lev1 on the screen).
Page 25
BQ80S V2 Variable-Speed Peristaltic Pump or Figure 23, and connect it to the DB15 port on the rear of the pump. CW_W RS_W Figure 22. Logic Level 2 Control with Internal 12V Power Source CW_W RS_W VCC_W 5V/12V/24V DC Figure 23. Logic Level 2 Control with External Power Source 2) Power on the pump.
BQ80S V2 Variable-Speed Peristaltic Pump speed; when the switch RS_W is open, the drive will stop. 6) When the switch CW_W is open, the drive will be running in the clockwise direction. When the switch CW_W is closed, the drive will be running in the counterclockwise direction.
BQ80S V2 Variable-Speed Peristaltic Pump Figure 26. RS485 MODBUS Wiring with Internal 12V Power Source 2) Power on the pump. The pump will display the main screen. 3) Use the MENU to change the mode to Internal Control mode or Time Dispense mode.
BQ80S V2 Variable-Speed Peristaltic Pump 9.2 Regular Maintenance 1) Always check the tubing and connections to avoid leakage. 2) Do not cover the fan on the rear of the pump. 3) Do not use water to wash the pump. Keep the pump head dry.
BQ80S V2 Variable-Speed Peristaltic Pump Hardware RS485 com 1. Check the wiring of the connector. does not 2. Check if the external control power work voltage is provided. 3. Check the connections of the communication board. Hardware Noisy when Check the screws and level on the pump running head to make sure they are secure.
BQ80S V2 Variable-Speed Peristaltic Pump 11 Naming Rule Drive Type Flow Rate Rotation Speed Version Pump type Function Code IP rating B: Step motor Q: Microflow 05: 50 rpm D: Fixed speed 1-9 for special Default: W: DC brushless T: Laboratory...