Golander pump BT100L Operation Manual

Golander pump BT100L Operation Manual

Intelligent flow peristaltic pump
Hide thumbs Also See for BT100L:

Advertisement

GOLANDER PUMP
Operation Manual
For Intelligent Flow Peristaltic Pump
BT100L, BT300L, BT600L
info@golanderpump.com
http://golanderpump.com
1-678-587-8806

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BT100L and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Golander pump BT100L

  • Page 1 GOLANDER PUMP Operation Manual For Intelligent Flow Peristaltic Pump BT100L, BT300L, BT600L info@golanderpump.com http://golanderpump.com 1-678-587-8806...
  • Page 2: Table Of Contents

    Contents Safety Cautions ................... 1 1 Description ..................1 2 Functions and Features ..............2 3 Components and Connectors ............3 4 Display Panel and Operating Keypads ..........4 4.1 Keypad ................... 4 4.2 LCD Touch Screen Display ............5 4.3 System Settings ..............
  • Page 3: Safety Cautions

    With RS485 MODBUS interface, the pump is easy to communicate with external device, such as PC, HMI or PLC. This pump series includes: • BT100L, flow rate: 0.00011-720 mL/min, speed: 0.1-150 rpm • BT300L, flow rate: 0.006-1600 mL/min,...
  • Page 4: Functions And Features

    BT-L Intelligent Flow Peristaltic Pump • BT600L, flow rate: 0.006-2900 mL/min, speed: 0.1-600 rpm 2 Functions and Features Advantage of peristaltic pump: Peristaltic pump can handle extremely viscous fluids, abrasive slurries and corrosive fluids. There is no seals in contact with the medium pumped and no valves to clog. The inner surfaces are smooth and easy to clean;...
  • Page 5: Components And Connectors

    BT-L Intelligent Flow Peristaltic Pump • Internal double-layer isolation structure, circuit board with conformal coating makes the pump dust-proof and moisture proof. • Anti-electromagnetic interference feature, wide input voltage range for complex power environment. • Stainless steel enclosure, easy to clean, resistant to the corrosion of the acid, alkali, sodium and organic solvents.
  • Page 6: Display Panel And Operating Keypads

    BT-L Intelligent Flow Peristaltic Pump 4 Display Panel and Operating Keypads LCD DISPLAY BT600L DIRECTION START/STOP PRIME DISPENSE Figure 2. Display Panel 4.1 Keypad START/STOP key. Press to start or stop drive. DIRECTION Key. Press to change the drive rotating direction, clockwise or counterclockwise.
  • Page 7: Lcd Touch Screen Display

    BT-L Intelligent Flow Peristaltic Pump 4.2 LCD Touch Screen Display 9.000 mL/min + - 150.0 RPM 4.3410 mL Figure 3. Main Display Screen 4.2.1 A - Keypad Lock Shows the state of the keypad lock. Press the icon to lock/unlock the keypad.
  • Page 8 BT-L Intelligent Flow Peristaltic Pump Tone on Tone off Figure 5. Key Tone 4.2.3 C - Control Mode Press the icon to enter the Control Mode interface. There are four control modes available. Control Mode Internal Ctrl Foot Ctrl Current Ctrl Voltage Ctrl Figure 6.
  • Page 9 BT-L Intelligent Flow Peristaltic Pump Internal Control Footswitch Current Control Voltage Control Mode Control Mode Mode Mode Figure 7. Control Mode Icon 4.2.4 D - Quick Settings Press the icon to enter Quick Settings interface to reset the cumulative volume and cycles. Quick Settings Cumulative Volume Clear...
  • Page 10 BT-L Intelligent Flow Peristaltic Pump Min:0.6ul/min Max:9.0ml/min -> Figure 9. Flow Rate Setting 4.2.7 G - Flow Rate Unit It shows current flow rate unit. When the drive is not running, press it to change the unit. The allowed units are µL/min, mL/min, L/min. 4.2.8 H - Fine Adjustment Button When the drive is running, press the fine adjustment button to adjust the...
  • Page 11: System Settings

    BT-L Intelligent Flow Peristaltic Pump Clockwise Counterclockwise Figure 11. Direction State When the drive is running, it will change to an animated icon as shown below. Figure 12. Running Animation 4.2.11 K - Tubing Size It shows current configured tubing size or pump head model. •...
  • Page 12 BT-L Intelligent Flow Peristaltic Pump Settings menu. Wizard Setup Calibrate Info About Return Figure 13. System Settings 4.3.1 Wizard A wizard to set up the parameters. The system will select appropriate tubing and pump head for you. 4.3.2 Calibrate Pump will accurately show current flow rate/volume after Flow Rate Calibration.
  • Page 13 BT-L Intelligent Flow Peristaltic Pump • PumpHead - Choose the model of the suitable pump head. Pump Head Setup Please choose pump head. YZ15 YZ15 YZ25 Figure 15. Pump Head Select • Tubing - Choose the appropriate tubing size for selected pump head.
  • Page 14 BT-L Intelligent Flow Peristaltic Pump IrDA Setup This function is to turn on/off IrDA control. Enable Return Figure 17. IrDA Setup • Language - Choose display language, Chinese or English. 语言选择 Language Select 中文 English Figure 18. Language Select • Remote It is the setting for external signal control: Logic Level control mode or Pulse control mode.
  • Page 15 BT-L Intelligent Flow Peristaltic Pump Remote Control Please choose remote control by logic level or pulse input. Pulse Figure 19. Remote Control Mode • Com It is the setting for RS485 MODBUS communication including baud rate, transmission mode and pump address. To change the address, click the address number on the screen, then input the value in the pop-up window.
  • Page 16 BT-L Intelligent Flow Peristaltic Pump Anti-Drip Settings Deceleration Time Reverse Speed Reverse Angle degrees Figure 21. Anti-Drip Setting 4.3.4 Info Information SysInfo Defaults WorkInfo Password Return Figure 22. Information It is about pump information. • Sysinfo It shows software version, memory size, internal temperature, etc.
  • Page 17 BT-L Intelligent Flow Peristaltic Pump System Information Software: V1.14 2012-02 Hardware: 16M FLASH Speed: 0.1RPM±0.2% 18 °C Temperature: Return Figure 23. System Information • Workinfo It shows total power on time, running time and power cycles. Work Information Power on time: 5 D 8 H 29 M Run time: 0 D 5 H 01 M Power Cycles: 0000038 T...
  • Page 18 BT-L Intelligent Flow Peristaltic Pump Factory Reset Warning! The system will be restored to factory default settings. Reset Return Figure 25. Factory Reset • Password Set a password to unlock the keypad. It will prevent user from changing parameters accidentally. The default password is empty. Please enter a password Enter Figure 26.
  • Page 19: External Control Interface

    BT-L Intelligent Flow Peristaltic Pump 5 External Control Interface DB15 Mark Note ADC_W Positive of external analog input Communication interface, B pole of RS485 Communication interface, A pole of RS485 VCC_W External DC power input Analog voltage signal output CW_W External input signal to control direction Pulse signal output Ground of external power...
  • Page 20: Power Connection

    BT-L Intelligent Flow Peristaltic Pump 6.2 Power Connection The voltage of the power supply should be marked on the sticker of the pump. Please make sure to use the right power source for the pump. Please plug the power cord into the IEC Power Connector on the rear of the pump and plug the opposite end of the power cord into an electrical outlet.
  • Page 21 BT-L Intelligent Flow Peristaltic Pump • Pump head is changed • Tubing is replaced • Transfer fluid in one channel with dual pump heads • Tubing is reinstalled • After continuous work for a long time How to calibrate 1) Install pump head and tubing. 2) In the General Settings window, set the model number of the installed pump head.
  • Page 22 BT-L Intelligent Flow Peristaltic Pump 13# Tubing Calibration 6.000 mL/min 3.000 Suggested testing vol >3.000mL to reach 0.5% precision. Next Return Figure 29. Flow Rate Calibration The flow rate 6.000 mL/min is the desired flow rate and 3.000 mL is the fluid volume need to test. The values or the units can change directly when press the button.
  • Page 23 BT-L Intelligent Flow Peristaltic Pump Press Next to enter Analyze and Calculate window. If you want to modify the test flow rate and liquid volume, press Prev button to re-enter the values. Note: If an accident occurs during the process of the test, please press START/STOP key to stop the test.
  • Page 24: Run Wizard

    BT-L Intelligent Flow Peristaltic Pump Analyze and Calculate No data. Please go back to re-enter the data or return to the main menu. Prev Return Figure 32. No Input Data 6.5 Run Wizard The system will help you to choose the appropriate pump head and tubing size automatically by running this wizard.
  • Page 25 BT-L Intelligent Flow Peristaltic Pump Please input the desired flow range. From 5.000 mL/min 6.000 mL/min Prev Next Return Figure 34. Flow Rate Input 3) Press Next button, system will list appropriate pump heads automatically. Select the desired pump head and tubing. If there is no pump head listed, go back to re-enter the data.
  • Page 26: Easy Dispense Mode

    BT-L Intelligent Flow Peristaltic Pump 6.6 Easy Dispense Mode The pump will dispense fluid by recording the volume for each dose. To record the volume for each dose 1) Turn on the power switch. The LCD display will be on. 2) On the Main Display Screen, Press PRIME key to fill tubing with fluid.
  • Page 27: External Control Mode

    BT-L Intelligent Flow Peristaltic Pump Note: If an accident occurs, press START/STOP key to stop dispensing at any time. 6.7 External Control Mode On this mode, logic level signal controls direction and start/stop. External analog signal controls rotating speed. The keypad is disabled. The analog signal could be 0-5V, 0-10V or 4-20mA.
  • Page 28 BT-L Intelligent Flow Peristaltic Pump CW_W ADC_W AGND RS_W 0-5V/0-10V /4-20mA Figure 40. DB15 Wiring with Internal 12VDC Power Source 2) Turn on the power switch. Pump will display the main screen. 3) Press to set Control Mode to voltage , or current 4) Turn on the external analog signal power source.
  • Page 29: Communication Mode

    BT-L Intelligent Flow Peristaltic Pump 9.000 9.000 mL/min mL/min 150.0 150.0 4.3410 4.3410 Voltage Control Mode Current Control Mode Figure 41. Control Mode Setting Note: The external DC power source can be 5V or 12V. If it is 24V, 1.5K resistor is needed to protect internal circuit.
  • Page 30 BT-L Intelligent Flow Peristaltic Pump 43, and connect it to the DB15 port on the rear of the pump. External DC power source is recommend to avoid electrical interference. VCC_W 12VDC Figure 43. RS485 MODBUS Wiring 2) Turn the power on. Pump will display the main screen. 3) On Internal Control Mode, when the main screen shows , the communication is connected.
  • Page 31: Footswitch

    BT-L Intelligent Flow Peristaltic Pump 6.9 Footswitch To use a footswitch to control start and stop 1) Power pump off. Wire the DB15 connector as shown on Figure 45 or Figure 46, and connect it to the DB15 port on the rear of the pump.
  • Page 32: Maintenance

    BT-L Intelligent Flow Peristaltic Pump 9.000 mL/min + - 150.0RPM 4.3410 Figure 47. Footswitch Control 7 Maintenance 7.1 Warranty The product comes with one-year labor and parts warranty. The limited warranty does not cover any damage that is caused by improper usage and handling.
  • Page 33 BT-L Intelligent Flow Peristaltic Pump between LCD and main control board. Hardware Motor does 1. Check the indicator of the not work driver board. 2. Check the wire connection between motor and driver board. 3. Check the wire connection between the driver and the main board.
  • Page 34 BT-L Intelligent Flow Peristaltic Pump communication board. Hardware Noisy when Check the screws and level on running pump head to make sure they are secure. Software External Check if pump is on External control does Control Mode. not work Software RS485 does 1.
  • Page 35: Dimensions

    BT-L Intelligent Flow Peristaltic Pump 8 Dimensions Figure 48. Dimensions (mm) 9 Naming Rule Drive Type Flow Rate Rotation Speed Version Pump type Function Code IP rating B: Step motor Q: Microflow 05: 50 rpm D: Fixed speed Default: 1-9 for special W: DC brushless T: Laboratory 08: 80 rpm...
  • Page 36: Specifications

    IP grade IP31 Display TFT Touch Screen LCD, 65536 Colors Dimensions (LxWxH) 226 x 150 x 238 mm (8.90 x 5.91 x 9.37 inch) Weight BT100L: 4.8 kg ( 10.6 lbs); BT300L: 5.3 kg (11.7 lbs); BT600L: 5.5 kg (12.1 lbs)
  • Page 37 BT-L Intelligent Flow Peristaltic Pump BT100L Suitable Pump Heads and Tubing, Flow Parameters Flow rate Drive Pump head Tubing size (mm) per channel type (mL/min) Wall:0.8~1, ID:≤2.4 DG6-1 (6rollers) 0.00016~26 Wall:0.8~1, ID:≤2.4 DG10-1(10rollers) 0.00011~20 Wall:0.8~1, ID:≤2.4 DG6-2 (6rollers) 0.00016~26 DG10-2 Wall:0.8~1, ID:≤2.4...
  • Page 38 BT-L Intelligent Flow Peristaltic Pump BT300L Suitable Pump Heads and Tubing, Flow Parameters Flow rate per Drive Pump Tubing size channel type head (mL/min) YZ15 13# 14# 16# 19# 25# 17# 0.006~990 YZ25 15# 24# 0.16~990 2 x YZ15 13# 14# 16# 19# 25# 17# 0.006~990 2 x YZ25 15# 24#...

This manual is also suitable for:

Bt300lBt600l

Table of Contents