5 Technical data

5 Technical data

5.1 Medium

Working medium:
Control medium:

5.2 Temperature

Media temperature:
Ambient temperature:
Control medium temper-
ature:
Storage temperature:

5.3 Pressure

Operating pressure:
Control pressure:

5.4 Actuator data

Filling volume:
Piston diameter:

5.5 Product compliance

Machinery Directive:

5.6 Mechanical data

Weight:
Installation position:
GEMÜ Q40
Please observe the tube manufacturer's specifications
Inert gases
Please observe the tube manufacturer's specifications
Actuator: 0 — 60 °C, Tube: Please observe the tube manufacturer's specifications
max. 60 °C
0 — 60 °C
max. 6 bar ,
Please observe the tube manufacturer's specifications
Normally closed (NC)
Normally open (NO)
Actuator size 0P1
Actuator size 1P1
Actuator size 2P1
Actuator size 0P1
Actuator size 1P1
Actuator size 2P1
2006/42/EC
Actuator size
0P1
1P1
2P1
Weights in kg
Optional
4 – 8 bar
2.5 – 4 bar
0.025 dm³
0.084 dm³
0.437 dm³
42 mm
60 mm
100 mm
Mounting flange
Stainless steel/PA6
FT
0
FT
0
FB
0
22 / 36
Tube holder
PA6
0.92
0.90
1.60
1.44
1.50
1.34
6.30
6.08
www.gemu-group.com
-
-
-
-