AC Power Source
waveforms start from SEQ-0, then SEQ-1、SEQ-2... in orders until time parameter (Time)
of SEQ-n being processed is 0 or SEQ-9 is finished outputting, then one List waveform
output is completed.
Following are definitions for all parameters:
Parameter
Count
V Start
V End
F Start
F End
DC Start
DC End
Time
Waveform
Degree On
After SEQ setting is completed, press
below:
Press
Enter
42
│ www.deltaww.com
Definition
Execution times for one complete List waveform.
When 0 is setting, output recycles endless until user
press
to stop.
Enter
Start voltage(V): (high voltage range)
: (low voltage range)
Stop voltage(V): (high voltage range)
: (low voltage range)
Start frequency(Hz)
Stop Frequency(Hz)
Output duration (msec)
Output waveform selection
Start phase angle for output waveform(deg)
to enter Trigger page as below:
ESC/
to return to LIST mode initialization page as
Cancel
Range
Min
Max
0
10000
0.0
300.0
0.0
150.0
0.0
300.0
0.0
150.0
30.0
1000.0
30.0
1000.0
0.0
±424.0
0.0
±424.0
0
60000
A or B
0.0
359.9