Cabinet temperature is too warm.
Cabinet is noisy.
Thermostat set too warm.
Blocking air flow.
Excessive amount of warm product
placed in cabinet.
Fuse blown or circuit breaker
tripped.
Dirty condenser coil.
Prolonged door opening or door
ajar.
Evaporator coil iced over.
Loose parts.
Tubing vibration.
11
Troubleshooting
Set thermostat to a lower
temperature.
Re-arrange product to allow for
proper air flow. Make sure there
is at least 4" of clearance from
evaporator.
Allow adequate time for product to
cool down.
Replace fuse or reset circuit
breaker.
Clean the condenser coil.
Ensure doors are closed when not
in use. Avoid opening doors for
long periods of time.
Locate and tighten the loose parts.
Ensure tubing is free from contact
with other tubing or components.