Omcan PT-CN-1270-HC Instruction Manual

Omcan PT-CN-1270-HC Instruction Manual

Refrigerated pizza prep units
Hide thumbs Also See for PT-CN-1270-HC:

Advertisement

Quick Links

Refrigerated Pizza Prep Units
Models PT-CN-1270-HC, 1829-HC, 2337-HC
Items 50042, 50043, 50044
Instruction Manual
Revised - 08/28/2019
Toll Free: 1-800-465-0234
Fax: 905-607-0234
Email: service@omcan.com
www.omcan.com

Advertisement

Table of Contents
loading

Summary of Contents for Omcan PT-CN-1270-HC

  • Page 1 Refrigerated Pizza Prep Units Models PT-CN-1270-HC, 1829-HC, 2337-HC Items 50042, 50043, 50044 Instruction Manual Revised - 08/28/2019 Toll Free: 1-800-465-0234 Fax: 905-607-0234 Email: service@omcan.com www.omcan.com...
  • Page 2: Table Of Contents

    Table of Contents Model PT-CN-1270-HC / Model PT-CN-1829-HC / Model PT-CN-2337-HC Section Page General Information --------------------------------------------------------------------------- 3 - 4 Safety and Warranty --------------------------------------------------------------------------- 4 - 5 Technical Specifications -------------------------------------------------------------------------- 6 Installation --------------------------------------------------------------------------------------- 6 - 8 Maintenance ------------------------------------------------------------------------------------- 8 - 9...
  • Page 3: General Information

    If the package has suffered rough handling, bumps or damage (visible or concealed), please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours, so we may initiate a claim with the carrier. A detailed report on the extent of the damage caused to the machine must be filled out within three days, from the delivery date shown in the shipping documents.
  • Page 4: Safety And Warranty

    Si el paquete ha sufrido un manejo de poco cuidado, golpes o daños (visible o oculto) por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro de las 24 horas, de modo que podamos iniciar una reclamación con la compañia.
  • Page 5 2 YEARS PARTS AND LABOUR / 5 YEARS PARTS ONLY ON COMPRESSOR WARRANTY Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule an Omcan authorized service technician to repair the equipment locally. Unauthorized maintenance will void the warranty. Warranty covers electrical and part failures, not improper use.
  • Page 6: Technical Specifications

    Technical Specifications Model PT-CN-1270-HC PT-CN-1829-HC PT-CN-2337-HC Temperature Range 0.5°C - 5°C / 33°F - 41°F Max Ambient 32°C / 90°F Temperature Rating Horsepower 1/6 HP 1/5 HP 1/4 HP Electrical 110V / 60Hz / 1Ph Amps 2.6A 3.4A 5.3A Refrigerant...
  • Page 7: Installation

    Installation • Install the unit in an indoor, well-ventilated area. - Unit performs more efficiently in a well-ventilated area. - For best performance, please maintain clearance of 6” on the back of the unit. - Outdoor use may cause decreased efficiency and damage to the unit. •...
  • Page 8: Maintenance

    Installation not be adjusted. The defrost timers automatically initiate at pre-set intervals and for a pre-determined duration. PLEASE NOTE: Excessive door opening should be avoided in order to maintain cabinet temperature and to eliminate the possibility of coil freeze-up. LOADING FOOD PANS Pizza prep units and sandwich prep units are designed to function with all pans in place, even if some pans are to be left empty.
  • Page 9: Troubleshooting

    Maintenance CLEANING THE INTERIOR OF UNIT • When cleaning the cabinet interior, use a solvent of warm water and mild soap. • Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the stainless steel surface. •...
  • Page 10 Troubleshooting Condensing unit runs for long Excessive amount of warm product Allow adequate time for Product to periods of time. Placed in cabinet. cool down. Prolonged door opening or door Ensure doors are closed when not ajar. in use. Avoid opening doors for long periods of time.
  • Page 11: Controller Instructions

    Controller Instructions Digital controller model: PJEZ for cooler Display and functions During normal operation, the controller displays the value of the probe set using parameter/4(=1 ambient probe, default, = 2 second probe, = 3 third probe).In addition, the display has LEDs that indicate the activation of the control functions (see Table 1), while the 3 buttons can be used to activate/deactivate some of the functions(see Table 2).
  • Page 12 Controller Instructions Table of Functions activated by the buttons - Models S, X, Y, C (Table 2) Button Normal Operation Start Up Pressing the Button Alone Pressed Together More than 3 sec: toggle ON/ Start/Stop ON/OFF continuous cycle Down More than 3 sec: start/stop Pressed For 1 sec.
  • Page 13 To exit the menu without saving the changed values (exit by timeout) do not press any button for at least 60 s. REFERENCE Item Number Model Number Description Manufacturer Model Number Refrigerated Prep Table Pizza 50042 PT-CN-1270-HC PICL1-HC 50” / 1270mm 110V/60/1 ETL cETLus Refrigerated Prep Table Pizza 50043 PT-CN-1829-HC PICL2-HC 72” / 1829mm 110V/60/1 ETL cETLus...
  • Page 14: Parts Breakdown

    Parts Breakdown Model PT-CN-1270-HC 50042...
  • Page 15 Parts Breakdown Model PT-CN-1270-HC 50042 Item No. Description Position Item No. Description Position Item No. Description Position AB462 Cabinet for PICL1-HC AB476 Evaporator for PICL1-HC AB159 Condenser for PICL1-HC Left Support of Evaporator Cover for AB463 Top Rail for PICL1-HC...
  • Page 16 Parts Breakdown Model PT-CN-1829-HC 50043...
  • Page 17 Parts Breakdown Model PT-CN-1829-HC 50043 Item No. Description Position Item No. Description Position Item No. Description Position Left Compressor Unit Track for AB496 Cabinet for PICL2-HC AB508 Right Lid Hinge for PICL2-HC AB524 PICL2-HC Right Compressor Unit Track for AB497 Top Rail for PICL2-HC AB509 Lid for PICL2-HC...
  • Page 18 Parts Breakdown Model PT-CN-2337-HC 50044...
  • Page 19: Parts Breakdown

    Parts Breakdown Model PT-CN-2337-HC 50044 Item No. Description Position Item No. Description Position Item No. Description Position Right Compressor Unit Track for AB532 Cabinet for PICL3-HC AB544 Right Lid Hinge for PICL3-HC AB560 PICL3-HC Compressor Unit Installation Board for AB533 Top Rail for PICL3-HC AB545 Lid for PICL3-HC...
  • Page 20: Electrical Schematics

    Electrical Schematics Model PT-CN-1270-HC 50042...
  • Page 21 Electrical Schematics Model PT-CN-1829-HC 50043...
  • Page 22: Electrical Schematics

    Electrical Schematics Model PT-CN-2337-HC 50044...
  • Page 23: Warranty Registration

    Warranty Registration Thank you for purchasing an Omcan product. To register your warranty for this product, complete the information below, tear off the card at the perforation and then send to the address specified below. You can also register online by visiting: Merci d’avoir acheté...
  • Page 24 Since 1951 Omcan has grown to become a leading distributor of equipment and supplies to the North American food service industry. Our success over these many years can be attributed to our commitment to strengthen and develop new and existing relationships with our valued customers and manufacturers.

This manual is also suitable for:

Pt-cn-1829-hcPt-cn-2337-hc500425004350044

Table of Contents