Maintenance
the fan motor to prevent moisture damage.
CLEANING THE INTERIOR OF THE UNIT
•
When cleaning the cabinet interior, us a solvent of warm water and mild soap.
•
Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the stainless steel
surface.
•
Wash door gaskets on a regular basis, preferably weekly. Simply remove door gasket from the frame of the
door, soak in warm water and soap for thirty (30) minutes, dry with a soft cloth and replace.
•
Check door gaskets for proper seal after they are replaced.
•
Periodically remove the shelves and pilasters from the unit and clean them with mild soap and warm water.
To remove the pilasters, first remove the shelves and shelf brackets. Then, simply lift the pilaster up and
out.
Warning: Disconnect power cord before cleaning any parts of the unit.
Troubleshooting
Problem
Compressor not running.
Condensing unit runs for long
periods of time.
Possible Cause
Fuse blown or circuit breaker
tripped.
Power cord unplugged.
Thermostat set too high.
Cabinet in defrost cycle.
Excessive amount of warm product
placed in cabinet.
Prolonged door opening or door
ajar.
Door gaskets not sealing properly.
Dirty condenser coil.
Evaporator coil iced over.
10
Solution
Replace fuse or reset circuit
breaker.
Plug in power cord.
Set thermostat to a lower
temperature.
Wait for defrost cycle to finish.
Allow adequate time for product to
cool down.
Ensure doors are closed when not
in use. Avoid opening doors for
long periods of time.
Ensure gaskets are snapped in
completely. Remove gaskets and
wash with soap and water. Check
condition of gaskets and replace if
necessary.
Clean the condenser coil.
Unplug unit and allow coil to
defrost. Make sure thermostat is
not set too cold. Ensure that the
door gaskets are sealing properly.
Need help?