Table of Contents Model RE-CN-0006-HC / Model RE-CN-0011-HC Model FR-CN-0686-HC / Model FR-CN-1219-HC Section Page General Information ------------------------------------------------------------------------------------------------------ 3 - 4 Safety and Warranty ----------------------------------------------------------------------------------------------------- 4 - 5 Technical Specifications ----------------------------------------------------------------------------------------------------- 6 Installation ------------------------------------------------------------------------------------------------------------------ 7 - 8 Maintenance ------------------------------------------------------------------------------------------------------------------- 9...
If the package has suffered rough handling, bumps or damage (visible or concealed), please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours, so we may initiate a claim with the carrier. A detailed report on the extent of the damage caused to the machine must be filled out within three days, from the delivery date shown in the shipping documents.
Si el paquete ha sufrido un manejo de poco cuidado, golpes o daños (visible o oculto) por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro de las 24 horas, de modo que podamos iniciar una reclamación con la compañia.
Page 5
2 YEARS PARTS AND LABOUR / 5 YEARS PARTS ONLY ON COMPRESSOR WARRANTY Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule an Omcan authorized service technician to repair the equipment locally. Unauthorized maintenance will void the warranty. Warranty covers electrical and part failures, not improper use.
Technical Specifications UNDERCOUNTER REFRIGERATORS Model RE-CN-0006-HC RE-CN-0011-HC Temperature Range 0.5°C - 5°C / 33°F - 41°F Power 1/6 HP 1/5 HP Refrigerant R290 Isolation Material Cyclopentane Cooling System Ventilated Defrosting Automatic Type of Controller Digital Number of Doors Number of Shelves...
Installation IMPORTANT!!!PLEASE READ BEFORE INSTALLATION • If the unit has recently been transported. Please let unit stand still for a minimum of 24 hours before plugging it in. • Make sure that the unit drops down to desired temperature before loading the unit with product. •...
Page 8
Installation will eventually result in a warmer cabinet temperature. LOADING PRODUCT Shelves have been factory-installed for your convenience. Before loading shelves, please be sure that all shelf clips are completely fastened in their correct locations. It is important that all shelves rest completely level before stocking your cabinet with product.
Maintenance CLEANING THE CONDENSER COIL • For efficient operation, it is important that the condenser surface be kept free of dust, dirt, and lint. • We recommend cleaning the condenser coil and fins at least once per month. • Clean with a commercial condenser coil cleaner, available from any kitchen equipment retailer. Brush the condenser fins from top to bottom, not side to side.
Troubleshooting Before requesting any service on your unit, please check the following points. Please note that this guide serve only as a reference for solutions to common problems. SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Compressor not running. Fuse blown or circuit breaker Replace fuse or reset circuit tripped.
Page 11
Troubleshooting Cabinet Temperature Is too warm. Thermostat set too warm. Set thermostat to lower Temperature. Blocking air flow. Re-arrange product to allow for Proper air flow. Make sure there Is at least four inches of clearance from evaporator. Excessive amount of warm product Allow adequate time for product to Placed in cabinet.
Controller Instructions Digital controller model: PJEZ for cooler Display and functions During normal operation, the controller displays the value of the probe set using parameter/4(=1 ambient probe, default, = 2 second probe, = 3 third probe).In addition, the display has LEDs that indicate the activation of the control functions (see Table 1), while the 3 buttons can be used to activate/deactivate some of the functions(see Table 2).
Page 13
Controller Instructions Table of Functions activated by the buttons - Models S, X, Y, C (Table 2) Button Normal Operation Start Up Pressing the Button Alone Pressed Together More than 3 sec: toggle ON/ Start/Stop ON/OFF continuous cycle Down More than 3 sec: start/stop Pressed For 1 sec.
Page 14
Controller Instructions • to display/set the values of the parameter displayed, press SET, then UP/DOWN and finally SET to confirm the changes (returning to the parameter menu). To save all the new values and exit the parameter menu, press SET for 3 s; To exit the menu without saving the changed values (exit by timeout) do not press any button for at least 60 s.
Page 15
Controller Instructions Light Auxiliary output light Auxiliary output light Anti-sweat heater function active not active active Service No malfunction Malfunction (eg. EEPROM error or probe fault) HACCP HACCP function HACCP function HACCP alarm (HA and/or enabled HF) not enabled Continuous Enabled Not enabled Request...
Page 16
Controller Instructions Accessing the configuration parameter (type F) 1. Hold the “ ” button for more than 5 s (if there are active alarms, first mute the buzzer), the display will show the first modifiable “F” parameter. Modifying the parameters After having displayed the parameter, either type “C”...
Page 17
Controller Instructions REFERENCE Item Number Model Number Description Manufacturer Model Number Refrigerator Under Counter 5.5 cu ft 50054 RE-CN-0006-HC UUC27R-HC 115V/60/1 ETL cETLus Refrigerator Under Counter 11.2 cu ft 50056 RE-CN-0011-HC UUC48R-HC 115V/60/1 ETL cETLus Freezer Under Counter 27” / 686mm...
Page 19
Parts Breakdown Model RE-CN-0006-HC 50054 Item No. Description Position Item No. Description Position Item No. Description Position AB143 Cabinet for UUC-27R-HC AB152 Thermostat for UUC-27R-HC AB161 Starter Kit for UUC-27R-HC 31 - 34 AB144 Top Board for UUC-27R-HC AB153 Stand Off Bracket for UUC-27R-HC...
Page 20
Parts Breakdown Model RE-CN-0011-HC 50056...
Page 21
Parts Breakdown Model RE-CN-0011-HC 50056 Item No. Description Position Item No. Description Position Item No. Description Position AB194 Cabinet for UUC-48R-HC AA743 4" Castor for UUC-48R-HC 64167 Compressor for UUC-48R-HC Thermostat Installation Board for UUC- AB195 Top Board for UUC-48R-HC AB204 AB214 Starter Kit for UUC-48R-HC...
Page 22
Parts Breakdown Model FR-CN-0686-HC 50053...
Page 23
Parts Breakdown Model FR-CN-0686-HC 50053 Item No. Description Position Item No. Description Position Item No. Description Position AB170 Cabinet for UUC-27F-HC AB179 Stand Off Bracket for UUC-27F-HC AB188 K Strip-3 Holes for UUC-27F-HC AB171 Top Board for UUC-27F-HC AB180 Compressor Unit Track for UUC-27F-HC AB189 K Strip-2 Holes for UUC-27F-HC AB172...
Page 24
Parts Breakdown Model FR-CN-1219-HC 50055...
Page 25
Parts Breakdown Model FR-CN-1219-HC 50055 Item No. Description Position Item No. Description Position Item No. Description Position AB223 Cabinet for UUC-48F-HC AB231 Thermostat for UUC-48F-HC AB241 Evaporator Cover for UUC-48F-HC AB224 Top Board for UUC-48F-HC AB232 Stand Off Bracket for UUC-48F-HC AB242 K Strip-3 Holes for UUC-48F-HC AB225...
Warranty Registration Thank you for purchasing an Omcan product. To register your warranty for this product, complete the information below, tear off the card at the perforation and then send to the address specified below. You can also register online by visiting: Merci d’avoir acheté...
Page 32
Since 1951 Omcan has grown to become a leading distributor of equipment and supplies to the North American food service industry. Our success over these many years can be attributed to our commitment to strengthen and develop new and existing relationships with our valued customers and manufacturers.
Need help?
Do you have a question about the RE-CN-0006-HC and is the answer not in the manual?
Questions and answers