2.9.2

Software Configuration Details

The software configuration is shown as a "tree" of data with headings that can be
expanded to show more data below them. The main menu itself and each button on the
main menu are displayed as a top-level item. Press the [+] symbol to expand an item to
show more details about the item. Different items will have different information
depending upon the software configuration.
• EXPAND ALL – Expands the software configuration tree to show all elements.
• CLOSE ALL – Closes the software configuration tree to only show the top most
items.
2.9.3

Software Configuration Error Indication

The PMAT 2000 Main Menu can detect configuration errors caused by missing or
incorrect files by comparing configuration document information with the revisions of
installed components. If the Main Menu detects a configuration error it will display the
word "Error" at the top level on the right hand side of the Software Configuration page.
Expand the top-level item to show the components and then expand the error section to
provide more detail about the particular error.
2.9.4

Software Configuration CRC

A Cyclical Redundancy Code (CRC) is calculated on the PMAT 2000 software
configuration. This CRC includes installed software; buttons, button titles, and button
hot keys; and dependent files for software applications. This number can be compared
between two PMAT 2000 to verify that both systems have the same software. This
information does not include log files, disk space used or any Loadable Software
Airplane Parts installed.
Each PMAT 2000 is delivered with all software conforming to a controlled configuration
document. If the software configuration CRC of the PMAT 2000 matches the CRC
indicated in the configuration document, the PMAT 2000 will display the Image part
number and revision number on the bottom line of the software configuration
information. The configuration document may only be available to the system
administrator.
2.9.5

Boot COM Port Configuration

The PMAT 2000 is equipped with changeable Input and Output options, which are
known as COM port configurations. This sets the COM port configuration that will be
set at boot time (default) but does not affect the current configuration.
2.9.6

Current COM Port Configuration

The PMAT 2000 is equipped with changeable Input and Output options, which are
known as COM port configurations. The value displayed in this window is the current
configuration. Select this to change the current COM port configuration. The PMAT
2000 will return to the Boot COM Port Configuration at the next boot.