Installing the AT 2000 communicator
4
The cable is supplied with the DE module.
The ribbon cable is used for all connections of the communicator input lines and for the
"Communicator Trouble" and "Negative Acknowledgment" communicator signals. If additional
signals are required for the communicator, e.g. area x armed / disarmed, these can be
provided as a point-to-point connection between the panel and communicator.
Notice!
The analog AT 2000 requires 12 V. Use the ribbon cable connector labeled AT 2000 Uext. The
analog AT 2000 also requires a separate 12 V power source, such as the ICP-MAP0017 12 V
converter.
The ISDN AT 2000 requires 28 V. Use the ribbon cable connector labeled AT 2000 28V.
Bosch Sicherheitssysteme GmbH
Connect the AT 2000 communicator to the ICP-MAP0007 DE module using the supplied
ribbon cable (P/N F01U074773).
Installation manual
Installation | en
29
2018.08 | 23 | F.01U.168.332