Maintenance
Code
Description
W270 Short-circuit and overload at output 1
W280 Short-circuit and overload at output 2
7.2
Firmware history
7.2.1
Release
The release number on the nameplate and in the Operating Instructions indicates the device
release: XX.YY.ZZ (example 01.02.01).
XX
• Change to main version
• No longer compatible
• The device and Operating Instructions change
YY
• Change to functionality and operation
• Compatible
• No changes to the Operating Instructions
ZZ
• Fixes and internal changes
• No changes to the Operating Instructions
7.2.2
Software history
Date
Software version
09.2018
01.02
04.2014
01.02
02.2006
01.02
8
Maintenance
Buildup on the sensor negatively affects measurement accuracy
‣
Check the sensor for buildup at regular intervals.
CAUTION
L
Damage to the device.
‣
Ensure that the process is unpressurized before you remove the device.
‣
Do not twist the device out of the process connection thread at the housing.
‣
Always use a suitable open-ended wrench to remove the device→ 38.
26
Remedial action
Check output wiring
Increase the load resistance at switch output 1
Check output wiring
Increase the load resistance at switch output 2
Software
Documentation
modifications
-
BA00229O/09/EN/
14.18
-
BA00229O/09/EN/
13.14
-
BA229O/09/EN/
06.09
Temperature switch OTR31, OTR35
Material number
71415688
71252257
71098141