Figure 5: Disable engine shutdown detection
When the engine shutdown detection has been switched off in Victron Connect ('forced charging') current will
be drawn from the starter battery even if the engine is not running.
During 'forced charging' the input voltage lockout is the only limit left to disable charging automatically, make
sure this level is not set too low, in most applications 12.5V is sufficiently low.
4.6. Cable and fuse recommendations
Figure 6: Cable and fuse recommendations
Voltage rating (Input or output)
12 V
24 V
4.7. Recommended torque
Torque: 1.6Nm
Figure 7: Tightening torques
Page 7
Orion-Tr Smart DC-DC Charger Isolated
External battery protection
Fuse
60 A
30 A
Minimum cable gauge
0.5m
1m
2m
2
2
2
6mm
10mm
10mm
2
2
2
4mm
6mm
6mm
5m
10m
2
2
16mm
16mm
2
2
10mm
10mm
Installation