MPPT solar charger manual

8.11.18. Error 119 - Settings data lost

The charger cannot read its configuration and has stopped. This error will not auto-reset.
Perform the below procedure to get it working again:
Error recovery:
• First, restore it to factory defaults. (top right in Victron Connect, click on the three dots).
• Disconnect the solar charger from all power sources.
• Wait 3 minutes, and power up again.
• Reconfigure the charger.
• Report this to your Victron dealer and ask for it to be escalated to Victron; as this error should never happen. Preferably include
firmware version and any other specifics (VRM URL, VictronConnect screenshots or similar).