5.1.2. Settings via the rotary switch

The rotary switch can be used to select eight pre-programmed battery charge algorithms.
Use a small flathead screwdriver to turn the rotary switch. The arrow indicates which setting number has been selected.
The table below indicates the charge algorithm and charge settings for each rotary switch position.
Turning the rotary switch will override the charge settings including settings that were made with the
VictronConnect app or with the display. Likewise, if charge settings are changed with the VictronConnect
app or the display, this will override the rotary switch setting.
Switch
Suggested
position
battery type
Gel long life
(OPzV)
0
Gel Exide A600
(OPzV)
Gel MK
Gel Victron
deep discharge
Gel Exide A200
AGM Victron
1
deep discharge
Stationary
tubular plate
(OPzS)
Default setting
Gel Victron
deep discharge
Gel Exide A200
2
AGM Victron
deep discharge
Stationary
tubular plate
(OPzS)
AGM spiral cell
Stationary
3
tubular plate
(OPzS)
Rolls AGM
PzS tubular
plate traction
4
batteries or
OPzS batteries
* The top value is for 12V systems, the middle for 24V systems and the bottom for 48V systems.
** Equalize is by default disabled. To enable see chapter
Page 18
MPPT solar charger manual
Rotary switch set to position 2
Float
Absorption
voltage*
voltage* (V)
(V)
14.1
13.8
28.2
27.6
56.4
55.2
14.3
13.8
28.6
27.6
57.2
55.2
14.4
13.8
28.8
27.6
57.6
55.2
14.7
13.8
29.4
27.6
58.8
55.2
14.9
13.8
29.8
27.6
59.6
55.2
Equalize**
Equalize**
nominal
voltage* (V)
current
percentage
15.9
31.8
8%
63.6
16.1
32.2
8%
64.4
16.2
32.4
8%
64.8
16.5
33.0
8%
66.0
16.7
33.4
25%
66.8
Battery settings [20]
Configuration and settings
Temperature
compensation
factor* (mV/°C)
-16
-32
-64
-16
-32
-64
-16
-32
-64
-16
-32
-64
-16
-32
-64