Victronconnect App Error Reporting; Monitoring Via A Gx Device And Vrm - Victron energy MPPT 150/70 Manual

Mppt solar charger
Hide thumbs Also See for MPPT 150/70:
Table of Contents

Advertisement

• Solar Vmax: The highest voltage (V) from the PV array during the day.
• Battery max and min: The first figure shows the maximum battery voltage (Vmax) for the day. The figure below is the minimum
battery voltage(Vmin) for the day.
• Errors: This shows the daily number of errors, if any. To get more information about the error(s), click the orange dot. You may
need to slide the display on your device up to see the errors.)
• Lifetime total: This shows the total energy converted by the installation (W and is not re-settable).
• Since reset: This shows how much energy has been converted by the installation since the last reset.
Clicking on any bar (day) in the graph will expand the information. It will show the time and percentage of the total charge time
that the solar charger has spent in each Bulk, Absorption and Float charge stage.
You can use the charge times to see if the PV array is properly sized for your requirements. A system that
never reaches the float stage may need more panels. Or perhaps the load should be reduced?
The history can be exported as a comma-separated file (CSV) by clicking the three connected dots symbol
at the top right of the history screen. The symbol varies, depending on what platform VictronConnect is used.
The history can be reset by clicking the clock with an arrow symbol

7.3.3. VictronConnect app error reporting

The VictronConnect app will indicate active errors while the app is actively connected to the solar charger. The error will show up
in a pop-up window on the status screen together with the error number, name and a short error description.
The VictronConnect app also displays historical errors. To see these errors, navigate to the "History" tab and look at the bottom of
each day column. An orange dot will indicate an error on that day.

7.4. Monitoring via a GX device and VRM

If the solar charger is connected to a
case of solar charger alarms or faults.
For more information see the GX device manual.
Page 44
MPPT solar charger manual
An active error and a historical error.
GX
device, all its data can be accessed via the GX device. The GX device will also notify in
GX device showing alarm notification and historic errors.
at the top right of the history screen.
or the save symbol
Monitoring

Advertisement

Table of Contents
loading

Table of Contents