Aaeon IMBM-H110A Manual page 43

Table of Contents

Advertisement

PWM/DC Voltage Output [255]
This item appears only when you set the previous item to [Manual Mode] and
allows you to set the voltage allocated for Fan Control. Input value range:
[0~255]
The following items appear only when you set Fan Control Mode to [Thermal
Cruise Mode].
Target Temperature [50]
Input value range: [0~127]
Tolerance of Temperature [0]
Input value range: [0~7]
Fan Out Start-Up Value [127]
Input value range: [0~255]
Fan Stop Duty [To Fan Out Stop Value]
Selects fan stop duty mode. Configuration options: [Down to 0] [To Fan Out
Stop Value]
Fan Out Stop Value [100]
The Fan Out value decreases to this value if the temperature reaches below
the lowest temperature limit. Input value range: [0~255]
Fan Out Stop Time [60]
Determines the amount of time it takes for the Fan Out value to fall from the
stop value to zero. Input value range: [0~255]
Critical Temperature [75]
Determines the amount of time Fan Out takes to decrease its value by one
step. Input value range: [0~255]
Fan Out Step Up Time [10]
Determines the amount of time Fan Out takes to increase its value by one
step. Input value range: [0~255]
Fan Out Step Down Time [10]
Determines the amount of time Fan Out takes to decrease its value by one
step in intervals of 0.1 seconds. Input value range: [0~255]