Switch On/Off Led End Position Signalling; Set Intermediate Positions; Set Running Direction Close (Black Section) - AUMA SQ 05.2 Operating Instructions Manual

Part-turn actuators auma norm actuator (without controls)
Hide thumbs Also See for SQ 05.2:
Table of Contents

Advertisement

Commissioning (optional equipment settings)
How to proceed 1. Operate valve in desired end position (OPEN/CLOSED).

11.3.3 Switch on/off LED end position signalling

How to proceed 1. Operate valve in one of the end positions (OPEN/CLOSED).

11.4 Set intermediate positions

11.4.1 Set running direction CLOSE (black section)

How to proceed 1. Move valve in direction CLOSE to desired intermediate position.
38
If the current value fluctuates (e.g. between 4.0 – 4.2mA), the
LED end position signalling [} 38]
ment.
2. Reduce current value: Press push button [S1].
(The current is reduced by 0.02 mA every time the push button is pressed.)
3. Increase current value: Press push button [S2].
(The current is increased by 0.02 mA every time the push button is pressed.)
The LED behaviour for end position reached can be set as follows: blinking/continuous
illumination or no illumination. During setting mode, end position signalling is switched
on.
2. Hold down push buttons [S1] or [S2] for approx. 3 seconds.
ð End position signalling is switched on or off.
Table 16: LED behaviour when end position signalling is switched on
Set output current
4 mA
0 mA
20 mA
Actuators equipped with DUO limit switching are equipped with two intermediate posi-
tion switches. One intermediate position may be set for each running direction.
Figure 38: Setting elements for limit switching
[3]
[2]
[1]
[1]
Setting spindle: Running direction
CLOSE (black section)
[3]
Mark: Intermediate position CLOSED
set (black section)
[5]
Pointer: Running direction OPEN (white
section)
must be switched off for current adjust-
LED behaviour in end position
LED is blinking slowly
LED is blinking fast
LED is illuminated
[2]
Pointer: Running direction CLOSE
(black section)
[4]
Setting spindle: Running direction
OPEN (white section)
[6]
Mark: Intermediate position OPEN set
(white section)
Switch on/off
[6]
[5]
[4]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sq 14.2Sqr 07.2Sqr 14.2

Table of Contents