Technical Data - ESAB LAF 1001 Instruction Manual

Hide thumbs Also See for LAF 1001:
Table of Contents

Advertisement

3 TECHNICAL DATA

3
TECHNICAL DATA
Mains voltage
Z
max
Primary current
Values of the conventional load:
100% duty cycle
60% duty cycle
Setting range SAW
S
sc min
No-load voltage
No-load power
Efficiency at maximum
current
Power factor at maximum
current
Apparent power I
at
2
maximum current
Active power I
at
2
maximum current
Operating temperature
Weight
Dimensions L × W × H
Isolation class transformer H
Enclosure class
Application class
Enclosure class
The IP code indicates the enclosure class, i.e. the degree of protection against penetration
by solid objects or water.
Equipment marked IP23 is intended for indoor and outdoor use.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.
0449 503 101
LAF 1001
380/400/415/500 V, 3~ 50 Hz
440/550 V, 3~ 60 Hz
0.04 Ohm
I
84 A
max
800 A/44 V
1000 A/44 V
100-1000 A/24-44 V
4.8 MVA
53 V
180 W
90%
0.95
51.6 kVA
48.9 kW
-10 to +40 °C (+14 to +104 °F) -10 to +40 °C (+14 to +104 °F)
330 kg (727.5 lb)
646 × 552 × 1090 mm
(25.4 × 21.7 × 42.9 in.)
IP23
- 8 -
LAF 1001M
230/380/400/415/500 V,
3~ 50 Hz
230/440/550 V, 3~ 60 Hz
0.04 Ohm
I
138 A
max
800 A/44 V
1000 A/44 V
100-1000 A/24-44 V
4.8 MVA
56 V
178 W
86%
0.96
52.9 kVA
51.0 kW
330 kg (727.5 lb)
646 × 552 × 1090 mm
(25.4 × 21.7 × 42.9 in.)
H
IP23