Package Checklist The Moxa EDS-G509 is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance. • 1 EDS-G509 EtherDevice Switch • RJ45 to DB9 console port cable •...
Page 3
Panel Views of EDS-G509 Front Panel: 1. 1 to 4: 10/100/1000 BaseT(X) port 2. 5 to 9: 10/100/1000 BaseT(X) or 100/1000Base SFP slot combo ports 3. PWR1: LED for power input 1 4. PWR2: LED for power input 2 5. FAULT: LED indicator 6.
DIN-Rail Mounting The aluminum DIN-Rail attachment plate should already be fixed to the back panel of the EDS-G509 when you take it out of the box. If you need to reattach the DIN-Rail attachment plate to the EDS-G509, make sure the stiff metal spring is situated towards the top, as shown in the following figures.
STEP 3—Once the screws are fixed to the wall, insert the four screw heads through the wide parts of the keyhole-shaped apertures, and then slide the EDS-G509 downwards, as indicated in the figure at the right. Tighten the four screws for more stability.
Please read and follow these guidelines: • Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point. NOTE: Do not run signal or communications wiring and power wiring through the same wire conduit.
Wiring the Redundant Power Inputs The EDS-G509 has two sets of power inputs—power input 1 and power input 2. The top two contacts and the bottom two contacts of the 6-pin terminal block connector on the EDS-G509’s top panel are used for the two digital inputs.
Page 8
RJ45 (10-pin) Console Port Pinouts Description – – – RJ45 (10-pin) to DB9 (F) Cable Wiring 10/100/1000BaseT(X) Ethernet Port Connection The 10/100/1000BaseT(X) ports located on Moxa EtherDevice Switch’s front panel are used to connect to Ethernet-enabled devices. Most users will choose to configure these ports for Auto MDI/MDI-X mode, in which case the port’s pinouts are adjusted automatically depending on the type of Ethernet cable used (straight-through or cross-over), and the type of device (NIC-type or HUB/Switch-type) connected to the port.
Page 9
RJ45 (8-pin) to RJ45 (8-pin) Cross-Over Cable Wiring 100BaseFX or 1000BaseSFP Fiber Port The Gigabit Ethernet ports on the EDS-G509 series are SFP slots, which require 100BaseFX SFP or Gigabit mini-GBIC fiber transceivers to work properly. Moxa provides complete transceiver models for various distance requirements.
Laser Beam. Turbo Ring DIP Switch Settings EDS-G509 series are plug-and-play managed redundant Ethernet switches. The proprietary Turbo Ring protocol was developed by Moxa to provide better network reliability and faster recovery time. Moxa Turbo Ring’s recovery time is less than 300 ms (Turbo Ring) or less than 50 ms...
Page 11
EDS-G509 Series DIP Switches The default setting for each DIP Switch is OFF. The following table explains the effect of setting the DIP Switch to the ON position. “Turbo Ring” DIP Switch Settings DIP 1 DIP 2 DIP 3 DIP 4...
LED Indicators The front panel of the Moxa EDS-G509 contains several LED indicators. The function of each LED is described in the following table: Color State Description Power is being supplied to power input P1. PWR1 AMBER Power is not being supplied to power input P1.