SPECIFIC CLEANING PROCEDURES
PPE Helmets
In the ultrasonic bath, preheat 1 part Omega AquaClean with 10 parts clean water to
a temperature of 125˚F.
Place the helmet(s) in the basket and add a lid to the basket to keep the helmet(s)
from floating.
Submerge the basket into the bath and clean for 5 minutes.
Once completed, remove the basket from the bath and rinse thoroughly.
Waterproof Flashlights
In the ultrasonic bath, preheat 1 part Omega AquaClean with 10 parts clean water to
a temperature of 120˚F to 130˚F.
Place the flashlight(s) in the basket and add a lid to the basket to keep the
flashlight(s) from floating.
Submerge the basket into the bath and clean for 10 minutes.
After the cycle has completed, inspect the flashlight(s). If they are cleaned to your
satisfaction, they can be rinsed.
If they need another cycle, submerge the basket again and run for another 10
minutes.
Once completed, remove the basket from the bath and rinse thoroughly.
Cylinders
In the ultrasonic bath, preheat 1 part Omega AquaClean with 10 parts clean water to
a temperature of 120˚F to 130˚F.
Place the cylinder in the basket and add a lid to the basket to keep the cylinder from
floating.
Submerge the basket into the bath and clean for 3-5 minutes.
12