SPECIFIC CLEANING PROCEDURES

Aluminum Housings

· In the ultrasonic bath, preheat 1 part OmegaSupreme with 10 parts clean water to a
temperature of 125˚F.
· Wipe off the readily accessible, exterior excess from the parts to be cleaned.
· Arrange the parts so that no trapped air exits in the interior when lowered.
· Set the time for 2-5 minutes and start the cleaning cycle.
· If additional cleaning is needed, at the end of the first cycle, rotate the parts 180˚ in
the basket so that the portion that was facing the bottom of the tank is now facing
the top and vice versa.
· Clean the parts for another 2-5 minutes.
· When completed, rinse the parts with clean, hot water that is 125˚F.
· Blow off excess moisture using compressed air or a hot air blower.

Cylinder Heads

· In the ultrasonic bath, preheat 1 part OmegaSupreme with 10 parts clean water to a
temperature of 165˚F.
· Using a basket, lower the part into the bath and clean for 20 minutes.
· At the end of the first cycle, rotate the part 180˚ and clean for an additional 25
minutes.
· Once the part is clean, remove from the bath and rinse using clean, hot water.
· Blow off excess water using compressed air.
· Part will flash dry.
· For more aggressive cleaning, use 1 part OmegaSupreme with 10 parts water.
NOTE: OmegaSupreme is a stronger detergent and can accelerate starbursts in the
aluminum surface.