1. General Information 1.1 Overview Thanks for choosing Jinko Solar PV modules. In order to ensure the PV modules are installed correctly, please read the following installation instructions carefully before modules are installed and used. Please remember that these products generate electricity and certain safety measures need to be taken to avoid danger.
Page 4
All instructions should be read and understood before attempting to install, wire, operate and maintain the module. Don’t lift up PV modules using the attached cables or the junction box. Do not touch live terminals with bare hands. Use insulated tools for electrical connections. ...
to the product. Do not clean the glass with chemicals. Only use tap water. Make sure the module surface temperature is cool to the touch. Cleaning modules with cool water when module surface temp is high may result in glass breakage. Do not brush paint or corrosive substances on the surface of the modules.
Page 6
other metal products, so as not to cause electric shock danger and damage the modules. Keep the PV module packed in the carton until installation. Once the modules are removed from the packing box, they should be installed and connected to the bus box in time. If they are not installed immediately, protective measures (such as adding rubber joint cover, etc.) should be taken on the connection head.
During the installation, disassembly, maintenance and any other related processes of the product, it is recommended that the force applied between the cable and the connector, the cable and the junction box be no more than 60N. 2.2 Installation Condition 2.2.1 Climate Condition Please install the modules in the following conditions: a) Operating temperature: within –40°...
installing module within the distance, protect the connectors or add dust plugs. After removing the dust plugs, connect the connectors immediately and take other anti-rust measures to prevent rust. When the modules are installed on the roof, they must be separated from the roof by more than 10cm to facilitate air circulation and heat dissipation.
This design load was then tested with a safety factor of 1.5 times. So Jinko modules are tested under a maximum downward pressure of 5400Pa and upward pressure of 2400Pa. When mounting modules in snow-prone or high-wind environments, special care should be taken to mount the modules in a manner that provides sufficient design strength while meeting local code requirements.
Page 10
Max. Design Pressure: 3600Pa (positive ) &1600Pa (negative) mechanical load Module type Module dimensions(mm) Height of the frame(mm) Group 65 & 74 1722*1134*30 1669*1122 &1685*1132 & Group 66 & 75 1686*1134 &1687*1134*30 Height of the frame(mm) Group 1 1650*992 & 1665*1002 Group 2 1665*992 &...
Page 11
Group 19 2031*1008 Group 21 2008*1002 Group 29 2031*1008 Group 45 2008*1002 Group 55 2008*1002 Group 71 & 80 2274*1134 & 2278*1134 Group 72 & 81 2230*1134 Height of the frame(mm) Group 24 1796*995 & 1796*998 Group 26 1822*1008 Group 28 1822*1008 1840*998 &...
Page 12
2393*1130 & 2385*1122 & Group 73 & 82 2408*1132 & 2411*1134 Group 83 & 84 2465*1134 Group 87 2465*1134 2465*1134 Table 1: Mechanical dimensions for bolt fitting method(four mounting holes) Note: The installation method of bolt fitting (four mounting holes) is based on the internal results in Jinko. The load described in this manual is the design load.
Note:The installation method of bolt fitting ( ) is based on the experimental results in Jinko. NEXTracker The design of the NexTracker tracking bracket, the selection of accessories and the installation of modules should be completed by a professional system installer, which can refer to Jinko's mechanical load. The load described in this manual is the design load.
Page 14
Middle modules installation Fringe modules installation Figure 4: PV module installed at the side with Clamp fitting method Composition Clamp type Dimension(mm) material End Clamp 39 x 50 x 42 (40 mm thickness) 39 x 60 x 42(For 1.5mm thickness frame) End Clamp 41.5 x 50 x 40 (35 mm thickness)
Page 15
types and installation locations are shown in figure 7 and table 6. When installing modules using clamps on the long side of the frame, the applicable product types and installation locations (The without C transparent backsheet series module) are shown in figure 8 and table 7.
Page 16
Group 30 1704*1008 Group 46 1684*1002 Group 57 1693*1029 Group 58 1693*1029 Group 59 1716*1032 Group 60 1716*1032 Group 56 1684*1002 1756*1039 & 1750*1039 & Group 64 1750*1038 Group 61 1693*1029 & 1692*1029 Group 62 1693*1029 & 1692*1029 1884*1122 & 1901*1132 & Group 67 &...
Page 17
Group 42 1868*1034 & 1878*1032 Group 44 1868*1034 & 1878*1032 1842*1021 & 1842*1024 & Group 48 1855*1029 & 1855*1032 1842*1021 & 1842*1024 Group 50 & 1855*1029 & 1855*1032 1842*1021 & 1842*1024 Group 52 & 1855*1029 & 1855*1032 1840*998*35(NP) Group 54 1841*1002*30(CDF)...
Page 18
2.3.2.2 Clamp Mounting on Short Sides of the Frames Figure 6: Installation of clamps on short side of frames 1067Pa (positive ) 1067Pa (positive ) Max. Design Pressure: &1067Pa (negative) &1067Pa (negative) Module type mechanical load mechanical load Module dimensions(mm) Height of the frame(mm)...
Page 19
Group 11 1987*992 & 2008*1002 Group 12 1956*992 & 1979*1002 Group 13 1987*992 & 2008*1002 Group 14 1956*992 & 1979*1002 Group 15 1987*992 & 2008*1002 Group 16 1956*992 & 1979*1002 Group 17 1987*992 & 2008*1002 1987*992 & 2008*1002 & Group 18 2031*1008 Group 19 2031*1008...
Page 20
2.3.2.3 Clamp Mounting on Long & Short Sides Figure 7: Installation methods of clamps on long and short sides Max. Design 1600Pa (positive ) &1600Pa 1600Pa (positive ) &1600Pa (negative) Pressure: (negative) mechanical load mechanical load Module type Module dimensions(mm) Height of the frame(mm)...
Page 21
1672*992 & 1704*1008 Group 20 1704*1008 Group 22 1684*1002 Group 30 1704*1008 Group 46 1684*1002 Group 64 1756*1039 Group 67 & 1903*1134 Group 76 Height of the frame(mm) 1956*992 & Group 10 1979*1002 1987*992 & Group 11 2008*1002 1956*992 & Group 12 1979*1002 1987*992 &...
Page 22
1868*1034 & Group 42 1878*1032 1868*1034 & Group 44 1878*1032 1842*1021 & 1842*1024 & Group 48 1855*1029 & 1855*1032 Height of the frame(mm) 2113*995 & Group 23 2113*998 2130*1002 & Group 25 2139*1008 2130*1002 & Group 27 2139*1008 2163*995 & 2167*997 Group 31 2167*998 &...
Page 23
2.3.2.4 Clamp Mounting on Long Sides of the Frames (The without C transparent backsheet series module) Figure 8: Installation methods of clamps on long sides 3600Pa (positive ) Max. Design Pressure: &1600Pa (negative) mechanical load Module type Module dimensions(mm) Height of the frame(mm) Group 19 2031*1008 Group 29...
3. Wiring and Connection a) Before this procedure, please read the operation instructions of the PV system carefully. Make wiring by Multi-connecting cables between the PV modules in series or parallel connection, which is determined by user’s configuration requirement for system power, current and voltage. When installing and connecting modules, the foam tube must be removed first, Jinko will not guarantee the safety of products and the consistency of technical parameters if the connecting heads and tools used are not officially specified by Jinko or are not installed according to the official...
Page 25
Figure 9:Ground installation of PV modules f) Follow the requirements of applicable local and national electrical codes. g) These modules contain factory installed by pass diode .If these modules are incorrectly connected to each other, the bypass diodes, cable or junction box may be damaged. h) The cable of the junction box is defined as L, as showed below in Figure 10.
i) It is recommend to use negatively grounded inverters to avoid the PID effect for non-PID free modules. j) If modules are connected in series, the total voltage is equal to the sum of individual voltages. The recommended as below, System voltage≥N*Voc[1+TCVoc* (Tmin-25)] Where module numbers in series...
a) A build up of dust or dirt on the module(s) front face will result in a decreased energy output. Clean the panel(s) preferably once per annum if possible (depend on site conditions) using a soft cloth dry or damp, as necessary. Water with high mineral content may leave deposits on the glass surface and is not recommended.
reliable, but such information including product specification (without limitations) and suggestions do not constitute a warranty, expresses or implied. Jinko reserve the right to change the manual, the PV produce, the specifications, or product information sheets without prior notice. Appendix 1: Applicable Products This document is applicable to the series of solar modules as listed below: With 6”...
Page 29
(xxx =270~350,in increment of 5) Group 7 JKMSxxxM-60-V-MX3 JKMSxxxM-60B-V-MX3 JKMSxxxM-60-MX3 JKMSxxxM-60B -MX3 JKMSxxxM-60L-V-MX3 JKMSxxxM-60BL-V-MX3 JKMSxxxM-60L- MX3 JKMSxxxM-60BL -MX3 (xxx =270~340,in increment of 5) Group 8 JKMSxxxM-60H-V-MX3 JKMSxxxM-60HB-V-MX3 JKMSxxxM-60H-MX3 JKMSxxxM-60HB-MX3 JKMSxxxM-60HL-V-MX3 JKMSxxxM-60HBL-V-MX3 JKMSxxxM-60HL-MX3 JKMSxxxM-60HBL-MX3 (xxx =270~340,in increment of 5) Group 9 JKMxxxM-60H-TV JKMxxxM-60HL-TV JKMxxxM-60H-T...
Page 30
JKMSxxxM-72H-TI JKMSxxxM-72H-V-TI JKMSxxxM-72HB-TI JKMSxxxM-72HB-V-TI (xxx =335~425,in increment of 5) JKMxxxM-72HL JKMxxxM-72HL-V JKMxxxM-72HBL (xxx =335~425,in increment of 5) Group 16 JKMSxxxM-72-V-MX3 JKMSxxxM-72B-V-MX3 JKMSxxxM-72-MX3 JKMSxxxM-72B-MX JKMSxxxM-72L-V-MX3 JKMSxxxM-72BL-V-MX3 JKMSxxxM-72L-MX3 JKMSxxxM-72BL-MX3 (xxx =335~395,in increment of 5) Group 17 JKMSxxxM-72H-V-MX3 JKMSxxxM-72HB-V-MX3 JKMSxxxM-72H-MX3 JKMSxxxM-72HB-MX3 JKMSxxxM-72HL-V-MX3 JKMSxxxM-72HBL-V-MX3 JKMSxxxM-72HL-MX3 JKMSxxxM-72HBL-MX3 (xxx =335~395,in increment of 5)
Page 31
Group 27 JKSN3-DCCA-xxx JKSN3-DHCA-xxx (xxx =410~440,in increment of 5) Group 28 JKSN3-CCCA-xxx JKSN3-CHCA-xxx (xxx =345~370,in increment of 5) Group 29 JKMxxxM-72H-MBB-TV JKMxxxM-72H-MBB-T (xxx =385~405,in increment of 5) Group 30 JKMxxxM-60H-MBB-TV JKMxxxM-60H-MBB-T (xxx =320~335,in increment of 5) Group 31 JKMxxxM-78H-V JKMxxxM-78H JKMSxxxM-78H-V-TI JKMSxxxM-78H-TI (xxx =405-465,in increment of 5)
Page 32
JKMxxxM-6RL3 JKMxxxM-6RL3-V-J JKMxxxM-6RL3-J JKMxxxM-6RL3-V JKMSxxxM-6RL3-V-TI JKMSxxxM-6RL3-TI (xxx = 360~415,in increment of 5) Group 41 JKMxxxM-7RL3-T JKMxxxM-7RL3-TV-J JKMxxxM-7RL3-T-J JKMxxxM-7RL3-TV (xxx = 420~475,in increment of 5) Group 42 JKMxxxM-6RL3-T JKMxxxM-6RL3-TV-J JKMxxxM-6RL3-T-J JKMxxxM-6RL3-TV (xxx = 355~400,in increment of 5) Group 43 JKMxxxN-7RL3-TV JKMxxxN-7RL3-T JKMxxxN-7RL3-TV-J JKMxxxN-7RL3-T-J (xxx = 425~475,in increment of 5)
Page 33
Group 53 JKMxxxM-78H-MBB JKMxxxM-78H-MBB-V JKMSxxxM-78H-MBB-TI JKMSxxxM-78H-MBB-V-TI JKMSxxxM-78H-MBB-V- (xxx = 440~465,in increment of 5) Group 54 JKMxxxM-66H-MBB JKMxxxM-66H-MBB-V JKMSxxxM-66H-MBB-TI JKMSxxxM-66H-MBB-V-TI JKMSxxxM-66H-MBB-V- (xxx = 370~390,in increment of 5) Group 55 JKMxxxN-72H-MBB-B JKMxxxN-72H-MBB-B-V JKMxxxN-72H-MBB-B-TI JKMxxxN-72H-MBB-B-V- TI (xxx = 380-400,in increment of 5) Group 56 JKMxxxN-60H-MBB-B JKMxxxN-60H-MBB-B-V JKMxxxN-60H-MBB-B-TI...
Page 34
425-460 (xxx = ,in increment of 5) Group 64 JKMxxxM-60HLM-V JKMxxxM-60HLM JKMSxxxM-60HLM-V-MX3 (xxx = 350-385,in increment of 5) JKMxxxM-60HLM-B-V JKMSxxxM-60HLM-B-V-MX3 (xxx =350-370,in increment of 5) JKMxxxM-60HLM-TV (xxx = 355-380 ,in increment of 5) Group 65 JKMxxxM-54HL4-V JKMxxxM-54HL4 (xxx = 360-415,in increment of 5) JKMxxxM-54HL4-B-V JKMxxxM-54HL4-B (xxx = 380-400,in increment of 5)
Page 35
JKMxxxM-66HL4-B-V JKMxxxM-66HL4-B (xxx = 465-490,in increment of 5) JKMxxxM-66HL4-TV (xxx = 440-500,in increment of 5) Group 70 JKMxxxM-6RL4-V JKMxxxM-6RL4 (xxx = 455-495,in increment of 5) JKMxxxM-6RL4-B-V JKMxxxM-6RL4-B (xxx = 455-485,in increment of 5) JKMxxxM-6RL4-TV (xxx = 445-495,in increment of 5) Group 71 JKMxxxM-72HL4-V-J JKMxxxM-72HL4-J...
Page 36
Group 75 JKMxxxN-5RL4-V JKMxxxN-5RL4 (xxx = 375-405,in increment of 5) JKMxxxN-5RL4-B-V JKMxxxN-5RL4-B (xxx = 375-395,in increment of 5) JKMxxxN-5RL4-TV (xxx = 365-405,in increment of 5) Group 76 JKMxxxN-60HL4-V JKMxxxN-60HL4 (xxx = 405-475,in increment of 5) JKMxxxN-60HL4-B-V JKMxxxN-60HL4-B (xxx = 425-445,in increment of 5) JKMxxxN-60HL4-TV (xxx = 400-450,in increment of 5) Group 77...
Page 37
(xxx = 510-535,in increment of 5) JKMxxxN-72HL4-TV JKMxxxN-72HL4-TV-J (xxx = 480-545,in increment of 5) Group 81 JKMxxxN-7TL4-V JKMxxxN-7TL4 JKMxxxN-7TL4-V-J JKMxxxN-7TL4-J (xxx = 495-570,in increment of 5) JKMxxxN-7TL4-B-V JKMxxxN-7TL4-B (xxx = 495-530,in increment of 5) JKMxxxN-7TL4-TV JKMxxxN-7TL4-TV-J (xxx = 480-570,in increment of 5) Group 82 JKMxxxN-7RL4-V JKMxxxN-7RL4...
L: large cell series module T/TV: transparent backsheet series module MX3: module with Z8S Junction Box MBB: nine busbar B: black backsheet L3: 163 large cell series module LM: 166 large cell series module ...
Need help?
Do you have a question about the JKM565N-72HL4-V and is the answer not in the manual?
Questions and answers