1. General Information 1.1 Overview Thanks for choosing Jinko Solar PV modules. In order to ensure the PV modules are installed correctly, please read the following installation instructions carefully before modules are installed and used. Please remember that these products generate electricity and certain safety measures need to be taken to avoid danger.
Page 4
All instructions should be read and understood before attempting to install, wire, operate and maintain the module. Don’t lift up PV modules using the attached cables or the junction box. Do not touch live terminals with bare hands. Use insulated tools for electrical connections. ...
to the product. Do not clean the glass with chemicals. Only use tap water. Make sure the module surface temperature is cool to the touch. Cleaning modules with cool water when module surface temp is high may result in glass breakage. Do not brush paint or corrosive substances on the surface of the modules.
Page 6
When installing or maintaining the photovoltaic system, please do not wear metal rings, watches and other metal products, so as not to cause electric shock danger and damage the modules. Keep the PV module packed in the carton until installation. Once the modules are removed from the packing box, they should be installed and connected to the bus box in time.
requirements, please confirm with Jinko and install it; During the installation, disassembly, maintenance and any other related processes of the product, it is recommended that the force applied between the cable and the connector, the cable and the junction box be no more than 60N. 2.2 Installation Condition 2.2.1 Climate Condition Please install the modules in the following conditions:...
installing module within the distance, protect the connectors or add dust plugs. After removing the dust plugs, connect the connectors immediately and take other anti-rust measures to prevent rust. When the modules are installed on the roof, they must be separated from the roof by more than 10cm to facilitate air circulation and heat dissipation.
2.3.1 Mounting with Bolts For mounting with bolts, the following modules in tables 1 are applicable. The frame of each module has 8 mounting holes (Length* Width: 14mm*9mm) used to secure the modules to support structure. Always use all the eight mounting holes to secure the modules. The module frame must be attached to a mounting rail using M8 corrosion-proof bolts together with spring washers and flat washers in eight symmetrical locations on the PV module.
Page 10
1701*1122 &1717*1132 & Group 65 & 74 1718*1134 & 1719*1134*30 1669*1122 &1685*1132 & Group 66 & 75 1686*1134 &1687*1134*30 Height of the frame(mm) Group 1 1650*992 & 1665*1002 Group 2 1665*992 & 1684*1002 Group 3 1650*992 & 1665*1002 Group 4 1665*992 &...
Page 11
Group 21 2008*1002 Group 29 2031*1008 Group 45 2008*1002 Group 55 2008*1002 Height of the frame(mm) 2096*1039 & 2090*1039 & Group 63 2090*1038 Group 85 2061*1023 Height of the frame(mm) Group 24 1796*995 & 1796*998 Group 26 1822*1008 Group 28 1822*1008 1840*998 &...
Page 12
The load described in this manual is the design load. When calculating the maximum test load, 1.5 times of safety factor should be considered. 2.3.1.2 Mounting with Bolts(four mounting holes) Figure 3: PV module installed with bolt fitting method(four mounting holes) Max.
Page 13
Group 15 1987*992 & 2008*1002 Group 16 1956*992 & 1979*1002 Group 17 1987*992 & 2008*1002 1987*992 & 2008*1002 & Group 18 2031*1008 Group 19 2031*1008 Group 21 2008*1002 Group 29 2031*1008 Group 45 2008*1002 Group 55 2008*1002 Group 71 & 80 2274*1134 &...
Page 14
2168*1021 & 2168*1024 Group 47 2182*1029 & 2182*1032 Group 49 2182*1029 Group 51 2182*1029 Group 53 2166*1002 2393*1130 & 2385*1122 & Group 73 & 82 2408*1132 & 2411*1134 Group 87 2465*1134 2465*1134 Table 2: Mechanical dimensions for bolt fitting method(four mounting holes) Note:...
JKMxxxN-78HL4-V 2465*1134 2465*1134 +1600/-1600 Table 3: Mechanical dimensions for bolt fitting method ( NEXTracker Note:The installation method of bolt fitting ( ) is based on the experimental results in Jinko. NEXTracker The design of the NexTracker tracking bracket, the selection of accessories and the installation of modules should be completed by a professional system installer, which can refer to Jinko's mechanical load.
Page 16
Middle modules installation Fringe modules installation Figure 5: PV module installed at the side with Clamp fitting method Composition Clamp type Dimension(mm) material End Clamp 39 x 50 x 42 (40 mm thickness) 39 x 60 x 42(For 1.5mm thickness frame) End Clamp 41.5 x 50 x 40 (35 mm thickness)
Page 17
types and installation locations are shown in figure 8 and table 7. When installing modules using clamps on the long side of the frame, the applicable product types and installation locations (The without C transparent backsheet series module) are shown in figure 9 and table 8.
Page 18
Group 22 1684*1002 Group 30 1704*1008 Group 46 1684*1002 Group 57 1693*1029 Group 58 1693*1029 Group 59 1716*1032 Group 60 1716*1032 Group 56 1684*1002 1756*1039 & 1750*1039 & Group 64 1750*1038 Group 61 1693*1029 & 1692*1029 Group 62 1693*1029 & 1692*1029 1884*1122 &...
Page 19
1842*1021 & 1842*1024 & Group 40 1855*1029 & 1855*1032 Group 42 1868*1034 & 1878*1032 Group 44 1868*1034 & 1878*1032 1842*1021 & 1842*1024 & Group 48 1855*1029 & 1855*1032 1842*1021 & 1842*1024 Group 50 & 1855*1029 & 1855*1032 1842*1021 & 1842*1024 Group 52 &...
Page 20
2.3.2.2 Clamp Mounting on Short Sides of the Frames Figure 7: Installation of clamps on short side of frames 1067Pa (positive ) 1067Pa (positive ) Max. Design Pressure: &1067Pa (negative) &1067Pa (negative) Module type mechanical load mechanical load Module dimensions(mm) Height of the frame(mm)...
Page 21
Group 11 1987*992 & 2008*1002 Group 12 1956*992 & 1979*1002 Group 13 1987*992 & 2008*1002 Group 14 1956*992 & 1979*1002 Group 15 1987*992 & 2008*1002 Group 16 1956*992 & 1979*1002 Group 17 1987*992 & 2008*1002 1987*992 & 2008*1002 & Group 18 2031*1008 Group 19 2031*1008...
Page 22
2.3.2.3 Clamp Mounting on Long & Short Sides Figure 8: Installation methods of clamps on long and short sides Max. Design 1600Pa (positive ) &1600Pa 1600Pa (positive ) &1600Pa (negative) Pressure: (negative) mechanical load mechanical load Module type Module dimensions(mm) Height of the frame(mm)...
Page 23
1672*992 & 1704*1008 Group 20 1704*1008 Group 22 1684*1002 Group 30 1704*1008 Group 46 1684*1002 Group 64 1756*1039 Group 67 & 1903*1134 Group 76 Height of the frame(mm) 1956*992 & Group 10 1979*1002 1987*992 & Group 11 2008*1002 1956*992 & Group 12 1979*1002 1987*992 &...
Page 24
1868*1034 & Group 42 1878*1032 1868*1034 & Group 44 1878*1032 1842*1021 & 1842*1024 & Group 48 1855*1029 & 1855*1032 Height of the frame(mm) 2113*995 & Group 23 2113*998 2130*1002 & Group 25 2139*1008 2130*1002 & Group 27 2139*1008 2163*995 & 2167*997 Group 31 2167*998 &...
Page 25
2.3.2.4 Clamp Mounting on Long Sides of the Frames (The without C transparent backsheet series module) Figure 9: Installation methods of clamps on long sides 3600Pa (positive ) Max. Design Pressure: &1600Pa (negative) mechanical load Module type Module dimensions(mm) Height of the frame(mm) Group 19 2031*1008 Group 29...
3. Wiring and Connection a) Before this procedure, please read the operation instructions of the PV system carefully. Make wiring by Multi-connecting cables between the PV modules in series or parallel connection, which is determined by user’s configuration requirement for system power, current and voltage. When installing and connecting modules, the foam tube must be removed first, Jinko will not guarantee the safety of products and the consistency of technical parameters if the connecting heads and tools used are not officially specified by Jinko or are not installed according to the official...
Page 27
Figure 10:Ground installation of PV modules f) Follow the requirements of applicable local and national electrical codes. g) These modules contain factory installed by pass diode .If these modules are incorrectly connected to each other, the bypass diodes, cable or junction box may be damaged. h) The cable of the junction box is defined as L, as showed below in Figure 11.
i) It is recommend to use negatively grounded inverters to avoid the PID effect for non-PID free modules. j) If modules are connected in series, the total voltage is equal to the sum of individual voltages. The recommended as below, System voltage≥N*Voc[1+TCVoc* (Tmin-25)] Where module numbers in series...
c) In order to reduce the potential for electrical and thermal shock, Jinko recommends cleaning PV modules during early morning or late afternoon hours when solar radiation is low and the modules are cooler, especially in regions with hotter temperatures. d) Never attempt to clean a PV module with broken glass or other signs of exposed wiring, as this presents a shock hazard.
Appendix 1: Applicable Products This document is applicable to the series of solar modules as listed below: With 6” poly and mono c-Si: Group 1 ① ② ③ JKMxxxPP JKMxxxPP-60(Plus) JKMS xxxPP-60 JKMSxxxPP-60-J ④ JKMxxxPP-60-V JKMxxxPP-60(Plus) -V JKMSxxxPP-60-V JKMSxxxPP-60-V-J JKMxxxPP-60B (xxx=260~290,in increment of 5) Group 2 JKMxxxPP-60H...
Page 31
Group 8 JKMSxxxM-60H-V-MX3 JKMSxxxM-60HB-V-MX3 JKMSxxxM-60H-MX3 JKMSxxxM-60HB-MX3 JKMSxxxM-60HL-V-MX3 JKMSxxxM-60HBL-V-MX3 JKMSxxxM-60HL-MX3 JKMSxxxM-60HBL-MX3 (xxx =270~340,in increment of 5) Group 9 JKMxxxM-60H-TV JKMxxxM-60HL-TV JKMxxxM-60H-T JKMxxxM-60HL-T (xxx =315~355,in increment of 5) JKMxxxN-60H-TV JKMxxxN-60HL-TV JKMxxxN-60H-T JKMxxxN-60HL-T (xxx =315~355,in increment of 5) Group 10 JKMxxxPP-72 JKMxxxPP-72(Plus) JKMSxxxPP-72 JKMSxxxPP-72-J JKMxxxPP-72-V JKMxxxPP-72(Plus)-V...
Page 32
JKMSxxxM-72-V-MX3 JKMSxxxM-72B-V-MX3 JKMSxxxM-72-MX3 JKMSxxxM-72B-MX JKMSxxxM-72L-V-MX3 JKMSxxxM-72BL-V-MX3 JKMSxxxM-72L-MX3 JKMSxxxM-72BL-MX3 (xxx =335~395,in increment of 5) Group 17 JKMSxxxM-72H-V-MX3 JKMSxxxM-72HB-V-MX3 JKMSxxxM-72H-MX3 JKMSxxxM-72HB-MX3 JKMSxxxM-72HL-V-MX3 JKMSxxxM-72HBL-V-MX3 JKMSxxxM-72HL-MX3 JKMSxxxM-72HBL-MX3 (xxx =335~395,in increment of 5) Group 18 JKMxxxM-72H-TV JKMxxxM-72HL-TV JKMxxxM-72H-T JKMxxxM-72HL-T (xxx =375~425,in increment of 5) JKMxxxN-72H-TV JKMxxxN-72HL-TV JKMxxxN-72H-T JKMxxxN-72HL-T...
Page 33
(xxx =345~370,in increment of 5) Group 29 JKMxxxM-72H-MBB-TV JKMxxxM-72H-MBB-T (xxx =385~405,in increment of 5) Group 30 JKMxxxM-60H-MBB-TV JKMxxxM-60H-MBB-T (xxx =320~335,in increment of 5) Group 31 JKMxxxM-78H-V JKMxxxM-78H JKMSxxxM-78H-V-TI JKMSxxxM-78H-TI (xxx =405-465,in increment of 5) Group 32 JKMxxxM-66H-V JKMxxxM-66H JKMSxxxM-66H-V-TI JKMSxxxM-66H-TI (xxx =340-390,in increment of 5) Group 33 JKMxxxM-78H-TV...
Page 34
(xxx = 420~475,in increment of 5) Group 42 JKMxxxM-6RL3-T JKMxxxM-6RL3-TV-J JKMxxxM-6RL3-T-J JKMxxxM-6RL3-TV (xxx = 355~400,in increment of 5) Group 43 JKMxxxN-7RL3-T JKMxxxN-7RL3-TV-J JKMxxxN-7RL3-T-J JKMxxxN-7RL3-TV (xxx = 425~475,in increment of 5) Group 44 JKMxxxN-6RL3-TV JKMxxxN-6RL3-T JKMxxxN-6RL3-TV-J JKMxxxN-6RL3-T-J (xxx = 355~400,in increment of 5) Group 45 JKMxxxN-72H-MBB-V JKMSxxxN-72H-MBB-TI...
Page 35
Group 54 JKMxxxM-66H-MBB JKMxxxM-66H-MBB-V JKMSxxxM-66H-MBB-TI JKMSxxxM-66H-MBB-V-TI JKMSxxxM-66H-MBB-V- (xxx = 370~390,in increment of 5) Group 55 JKMxxxN-72H-MBB-B JKMxxxN-72H-MBB-B-V JKMxxxN-72H-MBB-B-TI JKMxxxN-72H-MBB-B-V- TI (xxx = 380-400,in increment of 5) Group 56 JKMxxxN-60H-MBB-B JKMxxxN-60H-MBB-B-V JKMxxxN-60H-MBB-B-TI JKMxxxN-60H-MBB-B-V-TI (xxx = 315-330,in increment of 5) Group 57 JKMxxxM-6TL3-V JKMxxxM-6TL3 JKMSxxxM-6TL3-V-TI...
Page 36
JKMxxxM-60HLM-B-V JKMSxxxM-60HLM-B-V-MX3 (xxx =350-370,in increment of 5) JKMxxxM-60HLM-TV 355-380 (xxx = ,in increment of 5) Group 65 JKMxxxM-54HL4-V JKMxxxM-54HL4 (xxx = 360-415,in increment of 5) JKMxxxM-54HL4-B-V JKMxxxM-54HL4-B (xxx = 380-400,in increment of 5) JKMxxxM-54HL4-TV (xxx = 360-410,in increment of 5) Group 66 JKMxxxM-5RL4-V JKMxxxM-5RL4...
Page 37
Group 70 JKMxxxM-6RL4-V JKMxxxM-6RL4 (xxx = 455-495,in increment of 5) JKMxxxM-6RL4-B-V JKMxxxM-6RL4-B (xxx = 455-485,in increment of 5) JKMxxxM-6RL4-TV (xxx = 445-495,in increment of 5) Group 71 JKMxxxM-72HL4-V JKMxxxM-72HL4 JKMxxxM-72HL4-V-J JKMxxxM-72HL4-J (xxx = 475-555,in increment of 5) JKMxxxM-72HL4-B-V JKMxxxM-72HL4-B (xxx = 510-535,in increment of 5) JKMxxxM-72HL4-TV-J JKMxxxM-72HL4-TV (xxx = 475-550,in increment of 5)
Page 38
(xxx = 375-395,in increment of 5) JKMxxxN-5RL4-TV (xxx = 365-405,in increment of 5) Group 76 JKMxxxN-60HL4-V JKMxxxN-60HL4 (xxx = 405-475,in increment of 5) JKMxxxN-60HL4-B-V JKMxxxN-60HL4-B (xxx = 425-445,in increment of 5) JKMxxxN-60HL4-TV (xxx = 400-450,in increment of 5) Group 77 JKMxxxN-6TL4-V JKMxxxN-6TL4 (xxx = 415-450,in increment of 5)
Page 39
JKMxxxN-7TL4-V JKMxxxN-7TL4 JKMxxxN-7TL4-V-J JKMxxxN-7TL4-J (xxx = 495-570,in increment of 5) JKMxxxN-7TL4-B-V JKMxxxN-7TL4-B (xxx = 495-530,in increment of 5) JKMxxxN-7TL4-TV JKMxxxN-7TL4-TV-J (xxx = 480-570,in increment of 5) Group 82 JKMxxxN-7RL4-V-J JKMxxxN-7RL4-J JKMxxxN-7RL4-V JKMxxxN-7RL4 (xxx = 535-590,in increment of 5) JKMxxxN-7RL4-B-V JKMxxxN-7RL4-B (xxx = 540-575,in increment of 5) JKMxxxN-7RL4-TV JKMxxxN-7RL4-TV-J...
MBB: nine busbar B: black backsheet L3: 163 large cell series module LM: 166 large cell series module L4: 182 large cell series module TI: module with RSD Junction Box Jinko Cell Junction Wafer type Technology Module Type Cell...